Work Procedure
Perform the following procedures after replacing the multi-around monitor control unit.
- REPLACE MULTI-AROUND MONITOR CONTROL UNIT
Replace multi-around monitor control unit. Refer to REMOVAL AND INSTALLATION
>>
GO TO 2
- WRITING MAC KEY
Perform MAC key writing. Refer to DESCRIPTION .
>>
GO TO 3
- PERFORM CONFIGURATION CAUTION: When before writing the multi-around monitor control unit configuration, always writing the MAC key.
Perform configuration. Refer to DESCRIPTION .
>>
GO TO 4
- WRITING OF CALIBRATION DATA
Write the calibration data stored in the camera using M.U.T.-III SE. Refer to Work Procedure DIAGNOSIS PROCEDURE .
>>
GO TO 5
- PERFORM SELF-DIAGNOSIS
- Perform the self-diagnosis of multi-around monitor control unit with M.U.T.-III SE (Multi Around Monitor).
- Check if any DTC is detected.
Is any DTC detected?
YES >>
Perform the trouble diagnosis for the detected DTC. Refer to DTC INDEX .
NO >>
GO TO 6
- OPERATION CHECK
Confirm that the operation of the multi-around monitor and the camera image (reference line, expected route) are normal.
>>
WORK END