Data List Reference Table
The following items can be read by the scan tool from the ABS-ECU input data.
DATA LIST REFERENCE CHART
| No. | DATA LIST ITEM | CHECK CONDITIONS | NORMAL CONDITIONS |
|---|---|---|---|
| 01 | Failure continuation time 1* | Always | Maximum time to be stored: 9999 minutes (approximately seven days) |
| 02 | Failure continuation time 2* | Always | |
| 03 | Seat position | Slide the seat from the back-end position to the front-end position. | Rear/Front |
| 04 | Passenger seat Airbag Ignition | Do not apply any load to the passenger seat. | Permission/Prohibition |
| 05 | Driver seat Airbag Ignition | Do not apply any load to the driver seat. | Permission/Prohibition |
| 06 | Driving seatbelt (Buckle SW1) | Wear the driver seatbelt. | Unfastened/Fastened |
| 07 | Driving seatbelt (Buckle SW2) | Undo the driver seatbelt. | Fastened/Unfastened |
| 08 | Passenger seatbelt (Buckle SW1) | Wear the passenger seatbelt. | Unfastened/Fastened |
| 09 | Passenger seatbelt (Buckle SW2) | Undo the passenger seatbelt. | Fastened/Unfastened |
| 10 | Elimination times | Always | Maximum time to be stored: 255 days |
| 42 | OCSS Occupant Classification | Apply a load to the passenger seat | Class 0/Class 1/Class 2/Not Clear/- |
| 44 | OCSS Occupant Weight | kg/Unknown | |
| 45 | OCSS Parts Number | Always | - |
NOTE:
*:
- Failure continuation time 1 indicates the duration from the occurrence of failure to the first ignition signal output.
- Failure continuation time 2 indicates the duration from the first collision judgment or non-ignition judgment to the present.