Fastener Tightening Specifications
WARNING: This page is about a different variant/trim than selected.
FASTENER TIGHTENING SPECIFICATIONS
| ITEM | SPECIFICATION |
|---|---|
| Clutch fluid line bracket bolt | 18 +/- 3N.m (13 +/- 2 ft-lb) |
| Clutch tube flare nut | 15 +/- 1 N.m (11 +/- 1 ft-lb) |
| Clutch orifice mounting bolt < F5M42-2 > | 18 +/- 3 N.m (13 +/- 2 ft-lb) |
| Union bolt | 22 +/- 2 N.m (16 +/- 1 ft-lb) |
| Clutch release cylinder mounting bolt | 18 +/- 3 N.m (13 +/- 2 ft-lb) |
| Clutch cover mounting bolt | 18 +/- 3 N.m (13 +/- 2 ft-lb) |
| Fulcrum | 35 +/- 6 N.m (26 +/- 4 ft-lb) |