Checking The Operation Sound
- Check that the operation sound of the stepper motor can be heard from the EGR valve when the ignition switch is turned ON (without starting the engine).
- If the operation sound cannot be heard, inspect the drive circuit of the stepper motor.
NOTE:
If the operation sound is not heard, and the circuit is normal, either the stepper motor or the PCM may have failed.