DTC Set Conditions
Check conditions are where starting sequence was completed and battery positive voltage is higher than 10 volts. Judgement criteria is where battery backup line voltage has continued to be 6 volts or lower for 2 seconds.
Check conditions are where starting sequence was completed and battery positive voltage is higher than 10 volts. Judgement criteria is where battery backup line voltage has continued to be 6 volts or lower for 2 seconds.