Purge Control Valve (Turbo)
- Label and disconnect vacuum hoses from purge control valve. Valve is located under battery on Eclipse and near evaporation canister on Galant. Remove purge control valve. Connect a hand vacuum pump to nipple of valve where Red-striped hose was connected (control diaphragm). Apply 15.7 in. Hg to control diaphragm. If valve does not hold vacuum, replace valve.
- Blow air through purge passageway (blow through side leading to purge canister). If passageway is open with no vacuum applied to control diaphragm, replace purge control valve.
- Connect hand vacuum pump to nipple where Black hose was connected. Apply 15.7 in. Hg to control diaphragm. If valve does not hold vacuum, replace valve.