11 00 039 Checking compression of all cylinders (N14)
- Read out fault memory of DME control unit
- Check stored faults
- Rectify faults
- Delete fault memory
IMPORTANT:
High tension - mortal danger!
Interrupt power supply to ignition coils.
Interrupt power supply to ignition coils.
Necessary preliminary work:
- Remove SPARK PLUGS .
Unscrew tip (1) from special tool 11 0 222.
IMPORTANT:
Then check the Schrader valve that is now visible for secure seating.
Prepare special tool 11 0 222 in conjunction with 11 8 732 and 11 8 731.
Screw special tool 11 0 222 onto special tool 11 8 731 to 10 Nm.
IMPORTANT:
Do not to forget to coat spark plug thread of special tool 11 8 731 with oil.
Screw special tool 11 0 222 by hand into spark plug thread and connect special tool 11 0 224.
Use adapter lead (1) if the compression pressure is being checked with the BMW diagnosis system.
Depress accelerator pedal and operate starter motor until compression pressure stops rising.
Assemble engine
Clear diagnostic fault entries from fault memory.