Not Possible To Delete Faults In The MRS5K Using Quick Delete (SI M65 03 09)
Publication date: 2009-09-10Reference number: SI M65 03 09
NOT POSSIBLE TO DELETE FAULTS IN THE MRS5K USING QUICK DELETE
TECHNICAL SERVICE BULLETIN
Reference Number(s): SI M65 03 09, Date of Issue:
September 10, 2009
| MINI: | R50 (Cooper); R52 (Cooper and Cooper S Convertible); R53 (Cooper S) |
| GROUP: | Audio, Navigation, Monitors, Alarms, SRS |
SUBJECT
Not Possible to Delete Faults in the MRS5K Using Quick Delete
SITUATION
Following a quick delete in ISTA, fault codes for the MRS5K (Multiple Restraint System) remain in the fault memory list.
CAUSE
ISTA software error
PROCEDURE
- Rectify the cause of the MRS fault in the vehicle.
- Using the ISID, switch to the control unit tree diagram.
- Select the MRS control module.
- Select the "Call up CU functions" button.
- Select the "Component Actuation" tab.
- Select the "Clear fault code memory" menu item.
- Start the deletion process by selecting "Actuate Component".
- Perform a vehicle test to confirm that the faults have been successfully deleted.
WARRANTY INFORMATION
Information only.