Home >> Mercury >> 2009 >> Sable Base, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1256 (Engine Controls - Reference Values (Except Diesel & Hybrid)) >> Reference Value Parameter Identification (PID)/Measured Signal Chart

Reference Value Parameter Identification (PID)/Measured Signal Chart

WARNING: This page does not describe the selected car, but rather 32 other vehicles, including the 2009 Mercury Mountaineer, 2009 Mercury Milan, 2009 Mercury Mariner, 2009 Mercury Grand Marquis, and 2009 Lincoln Town Car. However, it is still accessible from the selected car via links, so may be relevant.

The following listing reflects PIDS and/or measured values which may reveal a possible concern within each system shown in chart. Match the category number with the related PID/measured signal and go to the TYPICAL DIAGNOSTIC REFERENCE VALUE CHARTS .

PID/MEASURED SIGNAL CHART

Category Number Related PIDS/Measured Signals
5-9-10-17 WAC/ACCR
5-9-10-17 ACCS
5-10-17 ACP
5-10-17 ACP V
5-21 AIR
5-21 AIRF
5-21 AIRM
1-23 APP1
1-23 APP2
1-23 APP3
23 BPP (BOO)
18-19 CHT
18-19 CHT V
1-2-3-5-6-7-11-12-13-14-15-16-17-20-21 CMP
1-2-3-5-6-7-11-12-13-14-15-16-17-20-21 CKP
1-2-3-5-6-7-11-12-13-14-15-16-17-20-21 CMP1/2
10 CPP/PNP
3-5-6-7-9-11-15-16-20-21 DPFEGR
4-18-19-21-22 ECT (1)
4-18-19-21-22 ECT V
3-5-6-7-9-11-15-16-20-21 EGRMC1-4
3-5-6-7-9-11-15-16-20-21 EGRMDSD
3-5-6-7-9-11-15-16-20-21 EGRVR
5-18-19-20-21 EOT
5-18-19-20-21 EOT V
22 EPC/EPC1/EPC2/EPC3
22 EPC V
3-5-6-11-21 EVAPCV
3-5-6-11-21 EVAPPDC
3-5-6-11-21 EVMV
19 FCV 3
20 FLI (H)
20 FLI V
1 thru 21 FP
1 thru 21 FPM or FP M
1 thru 21 FRP
1 thru 21 FRP V
1 thru 21 FRT
5 FTP
1 thru 21 FUELPW1/2
1 thru 21 FUELSYS (OL/CLSD-LP) (1)
22-23 GEAR
5 GENMON
19 HFC (FC3)
1 thru 21 HTR11/12/13/21/22
1 thru 21 IAC
2-3-5-7-8-10-22 IAT (1)
2-3-5-7-8-10-22 IAT2 (1)
5-14-15-16-17-20 IMRC
5-14-15-16-17-20 IMRCM
5-14-15-16-17-20 IMTV
6-11-12-14 thru 18-20-21 INJ x F
4-5-16-18-19-20-21 KNOCK 1 (1)
4-5-16-18-19-20-21 KNOCK 2 (1)
19 LFC (FCI)
1 thru 21 LONGFT1/2 (1)
1 thru 23 MAF (1)
1 thru 23 MAP
1 thru 22 MISF
1 thru 21 O2S11/12/13/21/22
22 OSS
10 PSP
10 PSPT
5 PTO
1 thru 23 RPM (1)
5-14-16-17 SCBC
5-14-16-17 SCIPC
1 thru 21 SHRTFT1/2/11/12/21/22
15-16-18-19-20-21 SPRKADV (1)
22-23 SS1(SSA)/SS2(SSB)/SS3(SSC)/SS4(SSD)
1-23 TACM (-)
1-23 TACM (+)
6-14-16-20 TCC
22 TCIL
22-23 TCS
22-23 TFT
1-23 TP
1-23 TP1 NS
1-23 TP2 PS
1-23 TP V
22-23 TR
22-23 TR 1-4
22-23 TR V
22-23 TR D
22-23 TSS
2-4-5-9-10-11-16-17-18-19-20-21 VCT
2-4-5-9-10-11-16-17-18-19-20-21 VCTDC1/2
1-2-3-5-6-11-12-13-14 VPWR
22-23 VSS
(1) Generic PID

Some signals can only be measured and require the use of a digital multimeter (DMM).