Battery Management System DTCS (BMS40)
BATTERY MANAGEMENT SYSTEM DTCS (BMS40)
| MB DTC | Description |
|---|---|
| B1A6857 | The access protection of the control unit has a malfunction. Incorrect or incompatible software modules were detected. |
| B210A00 | The power supply in the system is too low. |
| B210B00 | The power supply in the system is too high. |
| B284FFA | The squib for pyrofuse 'High-voltage on-board electrical system' has a malfunction. |
| B284FFB | The squib for pyrofuse 'High-voltage on-board electrical system' has a malfunction. |
| P00FD00 | The state of charge of high-voltage battery B is implausible. |
| P00FDFA | The state of charge of high-voltage battery B is implausible. |
| P00FDFB | The state of charge of high-voltage battery B is implausible. |
| P00FDFC | The state of charge of high-voltage battery B is implausible. |
| P0560FA | The on-board electrical system voltage has a malfunction. |
| P0560FB | The on-board electrical system voltage has a malfunction. |
| P056200 | The on-board power supply voltage is too low. |
| P056300 | The on-board power supply voltage is too high. |
| P057F00 | The charge level of the high-voltage battery is implausible. |
| P057FFA | The charge level of the high-voltage battery is implausible. |
| P057FFB | The charge level of the high-voltage battery is implausible. |
| P057FFC | The charge level of the high-voltage battery is implausible. |
| P060000 | Internal communication in the control unit has a malfunction. |
| P060049 | Internal communication in the control unit has a malfunction. There is an internal electrical fault. |
| P0600FA | Internal communication in the control unit has a malfunction. |
| P0600FB | Internal communication in the control unit has a malfunction. |
| P0600FC | Internal communication in the control unit has a malfunction. |
| P0600FD | Internal communication in the control unit has a malfunction. |
| P0600FE | Internal communication in the control unit has a malfunction. |
| P060400 | There is an internal control unit fault in the RAM memory. |
| P0604FA | There is an internal control unit fault in the RAM memory. |
| P0604FB | There is an internal control unit fault in the RAM memory. |
| P0604FC | There is an internal control unit fault in the RAM memory. |
| P060500 | There is an internal control unit fault in the ROM memory. |
| P0605FA | There is an internal control unit fault in the ROM memory. |
| P0605FB | There is an internal control unit fault in the ROM memory. |
| P0605FC | There is an internal control unit fault in the ROM memory. |
| P060600 | There is an internal control unit fault in the processor. |
| P0606FA | There is an internal control unit fault in the processor. |
| P0606FB | There is an internal control unit fault in the processor. |
| P0606FC | There is an internal control unit fault in the processor. |
| P060A00 | The monitoring function in the control unit has a malfunction. |
| P060BFA | There is an internal control unit fault in the analog/digital converter. |
| P060BFB | There is an internal control unit fault in the analog/digital converter. |
| P060BFC | There is an internal control unit fault in the analog/digital converter. |
| P062F00 | There is an internal error in the EEPROM of the control unit. |
| P062FFA | There is an internal error in the EEPROM of the control unit. |
| P062FFB | There is an internal error in the EEPROM of the control unit. |
| P062FFC | There is an internal error in the EEPROM of the control unit. |
| P062FFD | There is an internal error in the EEPROM of the control unit. |
| P062FFE | There is an internal error in the EEPROM of the control unit. |
| P062FFF | There is an internal error in the EEPROM of the control unit. |
| P06B100 | Output 1 for the power supply of the sensors has a short circuit to ground. |
| P06B1FA | Output 1 for the power supply of the sensors has a short circuit to ground. |
| P06B1FB | Output 1 for the power supply of the sensors has a short circuit to ground. |
| P06B200 | Output 1 for the power supply of the sensors has a short circuit to positive. |
| P06B2FA | Output 1 for the power supply of the sensors has a short circuit to positive. |
| P06B2FB | Output 1 for the power supply of the sensors has a short circuit to positive. |
| P06B400 | Output 2 for the power supply of the sensors has a short circuit to ground. |
| P06B500 | Output 2 for the power supply of the sensors has a short circuit to positive. |
| P0A0A00 | The interlock circuit of the high-voltage on-board electrical system has an electrical fault. |
| P0A0B00 | The interlock circuit of the high-voltage on-board electrical system has a malfunction. |
| P0A0BFB | The interlock circuit of the high-voltage on-board electrical system has a malfunction. |
| P0A0BFC | The interlock circuit of the high-voltage on-board electrical system has a malfunction. |
| P0A0C00 | The interlock circuit of the high-voltage on-board electrical system has a short circuit to ground. |
| P0A0D00 | The interlock circuit of the high-voltage on-board electrical system has a short circuit to positive. |
| P0A1FFA | There is an internal fault in control unit ""Battery"". |
| P0A1FFB | There is an internal fault in control unit ""Battery"". |
| P0A1FFC | There is an internal fault in control unit ""Battery"". |
| P0A1FFD | There is an internal fault in control unit ""Battery"". |
| P0A7D00 | The state of charge of the hybrid/high-voltage battery module is too low. |
| P0A7EFA | The hybrid/high-voltage battery module has overtemperature. |
| P0A7EFB | The hybrid/high-voltage battery module has overtemperature. |
| P0A7EFC | The hybrid/high-voltage battery module has overtemperature. |
| P0A7EFD | The hybrid/high-voltage battery module has overtemperature. |
| P0A7EFE | The hybrid/high-voltage battery module has overtemperature. |
| P0A7EFF | The hybrid/high-voltage battery module has overtemperature. |
| P0A7F00 | The state of health limit of the hybrid/high-voltage battery module has been reached. |
| P0A7FFA | The state of health limit of the hybrid/high-voltage battery module has been reached. |
| P0A7FFB | The state of health limit of the hybrid/high-voltage battery module has been reached. |
| P0A7FFC | The state of health limit of the hybrid/high-voltage battery module has been reached. |
| P0A7FFD | The state of health limit of the hybrid/high-voltage battery module has been reached. |
| P0A7FFE | The state of health limit of the hybrid/high-voltage battery module has been reached. |
| P0A7FFF | The state of health limit of the hybrid/high-voltage battery module has been reached. |
| P0A95FA | The electrical fuse for the high voltage has a malfunction. |
| P0A95FB | The electrical fuse for the high voltage has a malfunction. |
| P0A9C00 | Temperature sensor A of the hybrid/high-voltage battery has a malfunction. |
| P0A9D00 | Temperature sensor A of the hybrid/high-voltage battery has a short circuit to ground. |
| P0A9D85 | Temperature sensor A of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0A9E00 | Temperature sensor A of the hybrid/high-voltage battery has a short circuit to positive. |
| P0A9E84 | Temperature sensor A of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0A9F00 | Temperature sensor A of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0AA100 | The contact 'Positive terminal' of contactor A in the high-voltage battery is jammed closed. |
| P0AA1FA | The contact 'Positive terminal' of contactor A in the high-voltage battery is jammed closed. |
| P0AA1FB | The contact 'Positive terminal' of contactor A in the high-voltage battery is jammed closed. |
| P0AA200 | The contact 'Positive terminal' of contactor A in the high-voltage battery is jammed open. |
| P0AA2FA | The contact 'Positive terminal' of contactor A in the high-voltage battery is jammed open. |
| P0AA2FB | The contact 'Positive terminal' of contactor A in the high-voltage battery is jammed open. |
| P0AA400 | The contact 'Negative terminal' of contactor A in the high-voltage battery is jammed closed. |
| P0AA4FA | The contact 'Negative terminal' of contactor A in the high-voltage battery is jammed closed. |
| P0AA4FB | The contact 'Negative terminal' of contactor A in the high-voltage battery is jammed closed. |
| P0AA500 | The contact 'Negative terminal' of contactor A in the high-voltage battery is jammed open. |
| P0AA5FA | The contact 'Negative terminal' of contactor A in the high-voltage battery is jammed open. |
| P0AA5FB | The contact 'Negative terminal' of contactor A in the high-voltage battery is jammed open. |
| P0AA600 | There is an insulation fault in the hybrid/high-voltage on-board electrical system. |
| P0AA700 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. |
| P0AA7FA | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. |
| P0AA7FB | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. |
| P0AA800 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has a malfunction. |
| P0AA8FA | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has a malfunction. |
| P0AA8FB | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has a malfunction. |
| P0AAB00 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has a sporadic malfunction. |
| P0AABFA | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has a sporadic malfunction. |
| P0AABFB | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has a sporadic malfunction. |
| P0AABFC | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has a sporadic malfunction. |
| P0ABA02 | Sensor A for the battery voltage in the hybrid/high-voltage battery module has an electrical fault. There is a general signal fault. |
| P0ABB00 | Sensor A for the battery voltage in the hybrid/high-voltage battery module has a malfunction. |
| P0ABC00 | Sensor A for the battery voltage in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0ABD00 | Sensor A for the battery voltage in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0ABF00 | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P0ABF02 | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. There is a general signal fault. |
| P0ABF29 | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. There is an invalid signal. |
| P0ABF2F | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. There is an erratic signal. |
| P0ABF4B | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. There is a fault due to overtemperature. |
| P0ABFFA | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P0ABFFB | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P0ABFFC | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P0ABFFD | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P0ABFFE | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P0ABFFF | Sensor A for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P0AC0FA | Sensor A for the battery current in the hybrid/high-voltage battery module has a malfunction. |
| P0AC0FB | Sensor A for the battery current in the hybrid/high-voltage battery module has a malfunction. |
| P0AC100 | Sensor A for the battery current in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0AC1FA | Sensor A for the battery current in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0AC1FB | Sensor A for the battery current in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0AC200 | Sensor A for the battery current in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0AC2FA | Sensor A for the battery current in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0AC2FB | Sensor A for the battery current in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0AC3FA | Sensor A for the battery current in the hybrid/high-voltage battery module has a sporadic malfunction. |
| P0AC3FB | Sensor A for the battery current in the hybrid/high-voltage battery module has a sporadic malfunction. |
| P0AC600 | Temperature sensor B of the hybrid/high-voltage battery has a malfunction. |
| P0AC700 | Temperature sensor B of the hybrid/high-voltage battery has a short circuit to ground. |
| P0AC785 | Temperature sensor B of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0AC800 | Temperature sensor B of the hybrid/high-voltage battery has a short circuit to positive. |
| P0AC884 | Temperature sensor B of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0AC900 | Temperature sensor B of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0ACB00 | Temperature sensor C of the hybrid/high-voltage battery has a malfunction. |
| P0ACC00 | Temperature sensor C of the hybrid/high-voltage battery has a short circuit to ground. |
| P0ACC85 | Temperature sensor C of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0ACD00 | Temperature sensor C of the hybrid/high-voltage battery has a short circuit to positive. |
| P0ACD84 | Temperature sensor C of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0ACE00 | Temperature sensor C of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0AD900 | The actuation of the contact 'Positive terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault or an open circuit. |
| P0AD9FA | The actuation of the contact 'Positive terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault or an open circuit. |
| P0AD9FB | The actuation of the contact 'Positive terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault or an open circuit. |
| P0ADAFA | The actuation of the contact 'Positive terminal' of the contactor in the hybrid/high-voltage battery has a malfunction. |
| P0ADAFB | The actuation of the contact 'Positive terminal' of the contactor in the hybrid/high-voltage battery has a malfunction. |
| P0ADAFC | The actuation of the contact 'Positive terminal' of the contactor in the hybrid/high-voltage battery has a malfunction. |
| P0ADAFD | The actuation of the contact 'Positive terminal' of the contactor in the hybrid/high-voltage battery has a malfunction. |
| P0ADB00 | The actuation of the contact 'Positive terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to ground. |
| P0ADBFA | The actuation of the contact 'Positive terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to ground. |
| P0ADBFB | The actuation of the contact 'Positive terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to ground. |
| P0ADC00 | The actuation of the contact 'Positive terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to positive. |
| P0ADCFA | The actuation of the contact 'Positive terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to positive. |
| P0ADCFB | The actuation of the contact 'Positive terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to positive. |
| P0ADD00 | The actuation of the contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault or an open circuit. |
| P0ADDFA | The actuation of the contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault or an open circuit. |
| P0ADDFB | The actuation of the contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault or an open circuit. |
| P0ADF00 | The actuation of the contact 'Negative terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to ground. |
| P0ADFFA | The actuation of the contact 'Negative terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to ground. |
| P0ADFFB | The actuation of the contact 'Negative terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to ground. |
| P0AE000 | The actuation of the contact 'Negative terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to positive. |
| P0AE0FA | The actuation of the contact 'Negative terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to positive. |
| P0AE0FB | The actuation of the contact 'Negative terminal' of contactor A in the hybrid/high-voltage battery has a short circuit to positive. |
| P0AE200 | The switch 'Precharging' in the hybrid/high-voltage battery module is jammed in the closed position. |
| P0AE2FA | The switch 'Precharging' in the hybrid/high-voltage battery module is jammed in the closed position. |
| P0AE2FB | The switch 'Precharging' in the hybrid/high-voltage battery module is jammed in the closed position. |
| P0AE300 | The switch 'Precharging' in the hybrid/high-voltage battery module is jammed in the open position. |
| P0AE3FA | The switch 'Precharging' in the hybrid/high-voltage battery module is jammed in the open position. |
| P0AE3FB | The switch 'Precharging' in the hybrid/high-voltage battery module is jammed in the open position. |
| P0AE400 | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has an electrical fault or an open circuit. |
| P0AE4FA | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has an electrical fault or an open circuit. |
| P0AE4FB | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has an electrical fault or an open circuit. |
| P0AE600 | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has a short circuit to ground. |
| P0AE6FA | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has a short circuit to ground. |
| P0AE6FB | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has a short circuit to ground. |
| P0AE700 | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has a short circuit to positive. |
| P0AE7FA | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has a short circuit to positive. |
| P0AE7FB | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has a short circuit to positive. |
| P0AE900 | Temperature sensor D of the hybrid/high-voltage battery has a malfunction. |
| P0AEA00 | Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground. |
| P0AEA85 | Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0AEB00 | Temperature sensor D of the hybrid/high-voltage battery has a short circuit to positive. |
| P0AEB84 | Temperature sensor D of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0AEC00 | Temperature sensor D of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B0E00 | Sensor B for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P0B1000 | Sensor B for the battery current in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0B10FA | Sensor B for the battery current in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0B10FB | Sensor B for the battery current in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0B1100 | Sensor B for the battery current in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0B11FA | Sensor B for the battery current in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0B11FB | Sensor B for the battery current in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0B1300 | The values of sensors A and B for the battery current in the hybrid/high-voltage battery module are implausible in relation to each other. |
| P0B13FA | The values of sensors A and B for the battery current in the hybrid/high-voltage battery module are implausible in relation to each other. |
| P0B13FB | The values of sensors A and B for the battery current in the hybrid/high-voltage battery module are implausible in relation to each other. |
| P0B1500 | Sensor B for the battery voltage in the hybrid/high-voltage battery module has a malfunction. |
| P0B15FA | Sensor B for the battery voltage in the hybrid/high-voltage battery module has a malfunction. |
| P0B1600 | Sensor B for the battery voltage in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0B16FA | Sensor B for the battery voltage in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0B1700 | Sensor B for the battery voltage in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0B17FA | Sensor B for the battery voltage in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0B1902 | Sensor C for the battery voltage in the hybrid/high-voltage battery module has an electrical fault. There is a general signal fault. |
| P0B1A00 | Sensor C for the battery voltage in the hybrid/high-voltage battery module has a malfunction. |
| P0B1B00 | Sensor C for the battery voltage in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0B1C00 | Sensor C for the battery voltage in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0B2000 | Sensor D for the battery voltage in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0B20FA | Sensor D for the battery voltage in the hybrid/high-voltage battery module has a short circuit to ground. |
| P0B2100 | Sensor D for the battery voltage in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0B21FA | Sensor D for the battery voltage in the hybrid/high-voltage battery module has a short circuit to positive. |
| P0B3B00 | Sensor A for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B3C00 | Sensor A for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B3D00 | Sensor A for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B3E00 | Sensor A for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B3F00 | Sensor A for the battery voltage in the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B4000 | Sensor B for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B4100 | Sensor B for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B4200 | Sensor B for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B4300 | Sensor B for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B4400 | Sensor B for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B4500 | Sensor C for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B4600 | Sensor C for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B4700 | Sensor C for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B4800 | Sensor C for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B4900 | Sensor C for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B4A00 | Sensor D for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B4B00 | Sensor D for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B4C00 | Sensor D for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B4D00 | Sensor D for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B4E00 | Sensor D for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B4F00 | Sensor E for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B5000 | Sensor E for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B5100 | Sensor E for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B5200 | Sensor E for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B5300 | Sensor E for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B5400 | Sensor F for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B5500 | Sensor F for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B5600 | Sensor F for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B5700 | Sensor F for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B5800 | Sensor F for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B5900 | Sensor G for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B5A00 | Sensor G for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B5C00 | Sensor G for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B5E00 | Sensor H for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B5F00 | Sensor H for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B6100 | Sensor H for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B6300 | Sensor I for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B6400 | Sensor I for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B6500 | Sensor I for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B6600 | Sensor I for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B6700 | Sensor I for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B6800 | Sensor J for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B6900 | Sensor J for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B6A00 | Sensor J for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B6B00 | Sensor J for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B6C00 | Sensor J for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B6D00 | Sensor K for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B6E00 | Sensor K for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B6F00 | Sensor K for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B7000 | Sensor K for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B7100 | Sensor K for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B7200 | Sensor L for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B7300 | Sensor L for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7400 | Sensor L for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B7500 | Sensor L for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B7600 | Sensor L for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B7700 | Sensor M for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B7800 | Sensor M for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7900 | Sensor M for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B7A00 | Sensor M for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B7B00 | Sensor M for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B7C00 | Sensor N for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B7D00 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DE0 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DE1 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DE2 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DE3 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DE4 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DE5 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DFB | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DFC | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DFD | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DFE | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7DFF | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. |
| P0B7E00 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B7F00 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B8000 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0B8100 | Sensor O for the battery voltage of the hybrid/high-voltage battery has an electrical fault. |
| P0B8300 | Sensor O for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B8400 | Sensor O for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0B8800 | Sensor P for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. |
| P0B8900 | Sensor P for the battery voltage of the hybrid/high-voltage battery has a short circuit to positive. |
| P0BBD00 | The limit value for the difference between the cell voltages in the hybrid/high-voltage battery module has been exceeded. |
| P0BBE00 | The cell voltages in the hybrid/high-voltage battery module are different. |
| P0BC300 | Temperature sensor E of the hybrid/high-voltage battery has a malfunction. |
| P0BC400 | Temperature sensor E of the hybrid/high-voltage battery has a short circuit to ground. |
| P0BC485 | Temperature sensor E of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0BC500 | Temperature sensor E of the hybrid/high-voltage battery has a short circuit to positive. |
| P0BC584 | Temperature sensor E of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0BC600 | Temperature sensor E of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0C3000 | The charge level of the high-voltage battery module is too high. |
| P0C3400 | Temperature sensor F of the hybrid/high-voltage battery has a malfunction. |
| P0C3500 | Temperature sensor F of the hybrid/high-voltage battery has a short circuit to ground. |
| P0C3585 | Temperature sensor F of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0C3600 | Temperature sensor F of the hybrid/high-voltage battery has a short circuit to positive. |
| P0C3684 | Temperature sensor F of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0C3700 | Temperature sensor F of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0C7800 | The precharging time at battery string A of the high-voltage on-board electrical system is too long. |
| P0C7D00 | Temperature sensor G of the hybrid/high-voltage battery has a malfunction. |
| P0C7E00 | Temperature sensor G of the hybrid/high-voltage battery has a short circuit to ground. |
| P0C7F00 | Temperature sensor G of the hybrid/high-voltage battery has a short circuit to positive. |
| P0C8200 | Temperature sensor H of the hybrid/high-voltage battery has a malfunction. |
| P0C8300 | Temperature sensor H of the hybrid/high-voltage battery has a short circuit to ground. |
| P0C8400 | Temperature sensor H of the hybrid/high-voltage battery has a short circuit to positive. |
| P0C8900 | Temperature sensor I of the hybrid/high-voltage battery has a malfunction. |
| P0C8A00 | Temperature sensor I of the hybrid/high-voltage battery has a short circuit to ground. |
| P0C8A85 | Temperature sensor I of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0C8B00 | Temperature sensor I of the hybrid/high-voltage battery has a short circuit to positive. |
| P0C8B84 | Temperature sensor I of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0C8C00 | Temperature sensor I of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0C8E00 | Temperature sensor J of the hybrid/high-voltage battery has a malfunction. |
| P0C8F00 | Temperature sensor J of the hybrid/high-voltage battery has a short circuit to ground. |
| P0C8F85 | Temperature sensor J of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0C9000 | Temperature sensor J of the hybrid/high-voltage battery has a short circuit to positive. |
| P0C9084 | Temperature sensor J of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0C9100 | Temperature sensor J of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0C9300 | Temperature sensor K of the hybrid/high-voltage battery has a malfunction. |
| P0C9400 | Temperature sensor K of the hybrid/high-voltage battery has a short circuit to ground. |
| P0C9485 | Temperature sensor K of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0C9500 | Temperature sensor K of the hybrid/high-voltage battery has a short circuit to positive. |
| P0C9584 | Temperature sensor K of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0C9600 | Temperature sensor K of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0C9800 | Temperature sensor L of the hybrid/high-voltage battery has a malfunction. |
| P0C9900 | Temperature sensor L of the hybrid/high-voltage battery has a short circuit to ground. |
| P0C9985 | Temperature sensor L of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0C9A00 | Temperature sensor L of the hybrid/high-voltage battery has a short circuit to positive. |
| P0C9A84 | Temperature sensor L of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0C9B00 | Temperature sensor L of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0CA600 | The charging current of the hybrid/high-voltage battery is too high. |
| P0CA6FA | The charging current of the hybrid/high-voltage battery is too high. |
| P0CA6FB | The charging current of the hybrid/high-voltage battery is too high. |
| P0CA6FC | The charging current of the hybrid/high-voltage battery is too high. |
| P0CA6FD | The charging current of the hybrid/high-voltage battery is too high. |
| P0CA6FE | The charging current of the hybrid/high-voltage battery is too high. |
| P0CA6FF | The charging current of the hybrid/high-voltage battery is too high. |
| P0CA700 | The discharge current of the hybrid/high-voltage battery is too high. |
| P0CA7FA | The discharge current of the hybrid/high-voltage battery is too high. |
| P0CA7FB | The discharge current of the hybrid/high-voltage battery is too high. |
| P0CA7FC | The discharge current of the hybrid/high-voltage battery is too high. |
| P0CA7FD | The discharge current of the hybrid/high-voltage battery is too high. |
| P0CA7FE | The discharge current of the hybrid/high-voltage battery is too high. |
| P0CA7FF | The discharge current of the hybrid/high-voltage battery is too high. |
| P0CA900 | Temperature sensor M of the hybrid/high-voltage battery has a malfunction. |
| P0CAA00 | Temperature sensor M of the hybrid/high-voltage battery has a short circuit to ground. |
| P0CAA85 | Temperature sensor M of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0CAB00 | Temperature sensor M of the hybrid/high-voltage battery has a short circuit to positive. |
| P0CAB84 | Temperature sensor M of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0CAC00 | Temperature sensor M of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0CAE00 | Temperature sensor N of the hybrid/high-voltage battery has a malfunction. |
| P0CAF00 | Temperature sensor N of the hybrid/high-voltage battery has a short circuit to ground. |
| P0CAF85 | Temperature sensor N of the hybrid/high-voltage battery has a short circuit to ground. There is a signal above the permissible limit value. |
| P0CB000 | Temperature sensor N of the hybrid/high-voltage battery has a short circuit to positive. |
| P0CB084 | Temperature sensor N of the hybrid/high-voltage battery has a short circuit to positive. There is a signal below the permissible limit value. |
| P0CB100 | Temperature sensor N of the hybrid/high-voltage battery has a sporadic malfunction. |
| P0D0800 | Contact 'positive terminal' of contactor A of the on-board charger of the high-voltage battery is stuck closed. |
| P0D0900 | Contact 'positive terminal' of contactor A of the on-board charger of the high-voltage battery is stuck open. |
| P0D0A00 | Contact 'positive terminal' of contactor A of the on-board charger of the high-voltage battery has an electrical fault or open circuit. |
| P0D0C00 | Contact 'positive terminal' of contactor A of the on-board charger of the high-voltage battery has a short circuit to ground. |
| P0D0D00 | Contact 'positive terminal' of contactor A of the on-board charger of the high-voltage battery has a short circuit to positive. |
| P0D0F00 | Contact 'negative terminal' of contactor A of the on-board charger of the high-voltage battery is stuck closed. |
| P0D1000 | Contact 'negative terminal' of contactor A of the on-board charger of the high-voltage battery is stuck open. |
| P0D1100 | Contact 'negative terminal' of contactor A of the on-board charger of the high-voltage battery has an electrical fault or open circuit. |
| P0D1300 | Contact 'negative terminal' of contactor A of the on-board charger of the high-voltage battery has a short circuit to ground. |
| P0D1400 | Contact 'negative terminal' of contactor A of the on-board charger of the high-voltage battery has a short circuit to positive. |
| P0D26FA | The precharging time for the on-board charger is too long. There is a fault during AC charging. |
| P0D26FB | The precharging time for the on-board charger is too long. There is a fault during DC charging. |
| P0D3700 | The current value of the high-voltage battery is too high. |
| P0D37FA | The current value of the high-voltage battery is too high. |
| P0D37FB | The current value of the high-voltage battery is too high. |
| P0DAD00 | Circuit A for equalizing the cell voltages does not open. |
| P0DAE00 | Circuit A for equalizing the cell voltages does not close. |
| P0DAF00 | Circuit A for equalizing the cell voltages has a malfunction. |
| P0DB100 | Circuit B for equalizing the cell voltages does not open. |
| P0DB200 | Circuit B for equalizing the cell voltages does not close. |
| P0DB500 | Circuit C for equalizing the cell voltages does not open. |
| P0DB600 | Circuit C for equalizing the cell voltages does not close. |
| P0DB900 | Circuit D for equalizing the cell voltages does not open. |
| P0DBA00 | Circuit D for equalizing the cell voltages does not close. |
| P0DBD00 | Circuit E for equalizing the cell voltages does not open. |
| P0DBE00 | Circuit E for equalizing the cell voltages does not close. |
| P0DC100 | Circuit F for equalizing the cell voltages does not open. |
| P0DC200 | Circuit F for equalizing the cell voltages does not close. |
| P0DC500 | Circuit G for equalizing the cell voltages does not open. |
| P0DC600 | Circuit G for equalizing the cell voltages does not close. |
| P0DC900 | Circuit H for equalizing the cell voltages does not open. |
| P0DCA00 | Circuit H for equalizing the cell voltages does not close. |
| P0DCD00 | Circuit I for equalizing the cell voltages does not open. |
| P0DCE00 | Circuit I for equalizing the cell voltages does not close. |
| P0DD100 | Circuit J for equalizing the cell voltages does not open. |
| P0DD200 | Circuit J for equalizing the cell voltages does not close. |
| P0DD500 | Circuit K for equalizing the cell voltages does not open. |
| P0DD600 | Circuit K for equalizing the cell voltages does not close. |
| P0DD900 | Circuit L for equalizing the cell voltages does not open. |
| P0DDA00 | Circuit L for equalizing the cell voltages does not close. |
| P0E2DFA | There is an internal control unit fault in the monitoring function of the hybrid/high-voltage battery module. |
| P0E2DFB | There is an internal control unit fault in the monitoring function of the hybrid/high-voltage battery module. |
| P0E2DFC | There is an internal control unit fault in the monitoring function of the hybrid/high-voltage battery module. |
| P0E2F00 | Electrical fuse B for the high voltage has a malfunction. |
| P0E3000 | Electrical fuse C for the high voltage has a malfunction. |
| P0E6400 | The electric circuit for enabling the charger has a malfunction. |
| P0E7400 | There is a battery-internal insulation fault in the hybrid/high-voltage battery module. |
| P0E74FA | There is a battery-internal insulation fault in the hybrid/high-voltage battery module. |
| P0E74FB | There is a battery-internal insulation fault in the hybrid/high-voltage battery module. |
| P0EDD00 | The state of health limit of hybrid/high-voltage battery module B has been reached. |
| P0EDDFA | The state of health limit of hybrid/high-voltage battery module B has been reached. |
| P0EDDFB | The state of health limit of hybrid/high-voltage battery module B has been reached. |
| P0EDDFC | The state of health limit of hybrid/high-voltage battery module B has been reached. |
| P0EDDFD | The state of health limit of hybrid/high-voltage battery module B has been reached. |
| P0EDDFE | The state of health limit of hybrid/high-voltage battery module B has been reached. |
| P0EDDFF | The state of health limit of hybrid/high-voltage battery module B has been reached. |
| P0F0000 | Module A in the high-voltage battery has a malfunction. |
| P0F0100 | Module B in the high-voltage battery has a malfunction. |
| P0F0200 | Module C in the high-voltage battery has a malfunction. |
| P0F0300 | Module D in the high-voltage battery has a malfunction. |
| P0F0400 | Module E in the high-voltage battery has a malfunction. |
| P0F0500 | Module F in the high-voltage battery has a malfunction. |
| P0F0800 | Module I in the high-voltage battery has a malfunction. |
| P0F0900 | Module J in the high-voltage battery has a malfunction. |
| P0F0A00 | Module K in the high-voltage battery has a malfunction. |
| P0F0B00 | Module L in the high-voltage battery has a malfunction. |
| P0F0C00 | Module M in the high-voltage battery has a malfunction. |
| P0F0D00 | Module N in the high-voltage battery has a malfunction. |
| P0F10FA | The voltage at module A of the high-voltage battery is too high. |
| P0F10FB | The voltage at module A of the high-voltage battery is too high. |
| P0F10FD | The voltage at module A of the high-voltage battery is too high. |
| P0F11FA | The voltage at module B of the high-voltage battery is too high. |
| P0F11FB | The voltage at module B of the high-voltage battery is too high. |
| P0F11FD | The voltage at module B of the high-voltage battery is too high. |
| P0F12FA | The voltage at module C of the high-voltage battery is too high. |
| P0F12FB | The voltage at module C of the high-voltage battery is too high. |
| P0F12FD | The voltage at module C of the high-voltage battery is too high. |
| P0F13FA | The voltage at module D of the high-voltage battery is too high. |
| P0F13FB | The voltage at module D of the high-voltage battery is too high. |
| P0F13FD | The voltage at module D of the high-voltage battery is too high. |
| P0F14FA | The voltage at module E of the high-voltage battery is too high. |
| P0F14FB | The voltage at module E of the high-voltage battery is too high. |
| P0F14FD | The voltage at module E of the high-voltage battery is too high. |
| P0F15FA | The voltage at module F of the high-voltage battery is too high. |
| P0F15FB | The voltage at module F of the high-voltage battery is too high. |
| P0F15FD | The voltage at module F of the high-voltage battery is too high. |
| P0F18FA | The voltage at module I of the high-voltage battery is too high. |
| P0F18FB | The voltage at module I of the high-voltage battery is too high. |
| P0F18FD | The voltage at module I of the high-voltage battery is too high. |
| P0F19FA | The voltage at module J of the high-voltage battery is too high. |
| P0F19FB | The voltage at module J of the high-voltage battery is too high. |
| P0F19FD | The voltage at module J of the high-voltage battery is too high. |
| P0F1AFA | The voltage at module K of the high-voltage battery is too high. |
| P0F1AFB | The voltage at module K of the high-voltage battery is too high. |
| P0F1AFD | The voltage at module K of the high-voltage battery is too high. |
| P0F1BFA | The voltage at module L of the high-voltage battery is too high. |
| P0F1BFB | The voltage at module L of the high-voltage battery is too high. |
| P0F1BFD | The voltage at module L of the high-voltage battery is too high. |
| P0F1CFA | The voltage at module M of the high-voltage battery is too high. |
| P0F1CFB | The voltage at module M of the high-voltage battery is too high. |
| P0F1CFD | The voltage at module M of the high-voltage battery is too high. |
| P0F1DFA | The voltage at module N of the high-voltage battery is too high. |
| P0F1DFB | The voltage at module N of the high-voltage battery is too high. |
| P0F1DFD | The voltage at module N of the high-voltage battery is too high. |
| P0F20FA | Module A in the high-voltage battery has overtemperature. |
| P0F20FB | Module A in the high-voltage battery has overtemperature. |
| P0F21FA | Module B in the high-voltage battery has overtemperature. |
| P0F21FB | Module B in the high-voltage battery has overtemperature. |
| P0F22FA | Module C in the high-voltage battery has overtemperature. |
| P0F22FB | Module C in the high-voltage battery has overtemperature. |
| P0F23FA | Module D in the high-voltage battery has overtemperature. |
| P0F23FB | Module D in the high-voltage battery has overtemperature. |
| P0F24FA | Module E in the high-voltage battery has overtemperature. |
| P0F24FB | Module E in the high-voltage battery has overtemperature. |
| P0F25FA | Module F in the high-voltage battery has overtemperature. |
| P0F25FB | Module F in the high-voltage battery has overtemperature. |
| P0F28FA | Module I in the high-voltage battery has overtemperature. |
| P0F28FB | Module I in the high-voltage battery has overtemperature. |
| P0F29FA | Module J in the high-voltage battery has overtemperature. |
| P0F29FB | Module J in the high-voltage battery has overtemperature. |
| P0F2AFA | Module K in the high-voltage battery has overtemperature. |
| P0F2AFB | Module K in the high-voltage battery has overtemperature. |
| P0F2BFA | Module L in the high-voltage battery has overtemperature. |
| P0F2BFB | Module L in the high-voltage battery has overtemperature. |
| P0F2CFA | Module M in the high-voltage battery has overtemperature. |
| P0F2CFB | Module M in the high-voltage battery has overtemperature. |
| P0F2DFA | Module N in the high-voltage battery has overtemperature. |
| P0F2DFB | Module N in the high-voltage battery has overtemperature. |
| P0F5CFA | The voltage at module A of the high-voltage battery is too low. |
| P0F5CFB | The voltage at module A of the high-voltage battery is too low. |
| P0F5CFD | The voltage at module A of the high-voltage battery is too low. |
| P0F5DFA | The voltage at module B of the high-voltage battery is too low. |
| P0F5DFB | The voltage at module B of the high-voltage battery is too low. |
| P0F5DFD | The voltage at module B of the high-voltage battery is too low. |
| P0F5EFA | The voltage at module C of the high-voltage battery is too low. |
| P0F5EFB | The voltage at module C of the high-voltage battery is too low. |
| P0F5EFD | The voltage at module C of the high-voltage battery is too low. |
| P0F5FFA | The voltage at module D of the high-voltage battery is too low. |
| P0F5FFB | The voltage at module D of the high-voltage battery is too low. |
| P0F5FFD | The voltage at module D of the high-voltage battery is too low. |
| P0F60FA | The voltage at module E of the high-voltage battery is too low. |
| P0F60FB | The voltage at module E of the high-voltage battery is too low. |
| P0F60FD | The voltage at module E of the high-voltage battery is too low. |
| P0F61FA | The voltage at module F of the high-voltage battery is too low. |
| P0F61FB | The voltage at module F of the high-voltage battery is too low. |
| P0F61FD | The voltage at module F of the high-voltage battery is too low. |
| P0F64FA | The voltage at module I of the high-voltage battery is too low. |
| P0F64FB | The voltage at module I of the high-voltage battery is too low. |
| P0F64FD | The voltage at module I of the high-voltage battery is too low. |
| P0F65FA | The voltage at module J of the high-voltage battery is too low. |
| P0F65FB | The voltage at module J of the high-voltage battery is too low. |
| P0F65FD | The voltage at module J of the high-voltage battery is too low. |
| P0F66FA | The voltage at module K of the high-voltage battery is too low. |
| P0F66FB | The voltage at module K of the high-voltage battery is too low. |
| P0F66FD | The voltage at module K of the high-voltage battery is too low. |
| P0F67FA | The voltage at module L of the high-voltage battery is too low. |
| P0F67FB | The voltage at module L of the high-voltage battery is too low. |
| P0F67FD | The voltage at module L of the high-voltage battery is too low. |
| P0F68FA | The voltage at module M of the high-voltage battery is too low. |
| P0F68FB | The voltage at module M of the high-voltage battery is too low. |
| P0F68FD | The voltage at module M of the high-voltage battery is too low. |
| P0F69FA | The voltage at module N of the high-voltage battery is too low. |
| P0F69FB | The voltage at module N of the high-voltage battery is too low. |
| P0F69FD | The voltage at module N of the high-voltage battery is too low. |
| P112900 | Frequency counter 'Switching cycles of contactor' of on-board charger has reached its final value. |
| P113000 | Frequency counter 'Switching cycles of contactor' of on-board DC current charge-connection unit has reached its final value. |
| P113185 | Frequency counter 'Switching cycles of contactor' of on-board charger will soon have reached its final value. There is a signal above the permissible limit value. |
| P113285 | Frequency counter 'Switching cycles of contactor' of on-board DC current charge-connection unit will soon have reached its final value. There is a signal above the permissible limit value. |
| P113500 | The number of valid temperature sensors of the high-voltage battery is not sufficient. |
| P1135FA | The number of valid temperature sensors of the high-voltage battery is not sufficient. |
| P1136FA | The contacts 'Negative and positive terminals of contactors' in the high-voltage battery jam in the closed position. |
| P1136FB | The contacts 'Negative and positive terminals of contactors' in the high-voltage battery jam in the closed position. |
| P142A00 | There is a vehicle-side isolation alert in the high-voltage on-board electrical system. |
| P154000 | There is an advance warning about a low state of charge of the high-voltage battery. |
| P164456 | An incorrect variant coding or configuration was detected. An incorrect or incompatible configuration was detected. |
| P180A00 | The analog input for the crash signal has detected a crash event. |
| P181000 | The control unit 'High-voltage battery' has detected a thermal runaway. |
| P1A2200 | The values for the charge level of the high-voltage battery are implausible relative to each other. |
| P1A2300 | The temperature values of the high-voltage battery are implausible in relation to each other. |
| P1B1A00 | There is an overtemperature warning for the high-voltage battery module. |
| P1C8000 | The high-voltage component lockout is active. |
| P1C80FA | The high-voltage component lockout is active. |
| P1C9000 | Several temperature sensors in the high-voltage battery module have a malfunction. |
| P1C90FA | Several temperature sensors in the high-voltage battery module have a malfunction. |
| P1CA000 | Initial startup was not performed. |
| P1CB400 | The power supply for circuit 30c has a malfunction. |
| P1CB600 | The power supply for circuit 30c is too high. |
| P1CB700 | The power supply for circuit 30c is too low. |
| P1CB800 | The power supply for circuit 30c is implausible. |
| P1CB8FA | The power supply for circuit 30c is implausible. |
| P1CB8FB | The power supply for circuit 30c is implausible. |
| P1D2700 | Frequency counter 'Switching cycles of contactors' of high-voltage battery module will soon reach its final value. |
| P1D27FA | Frequency counter 'Switching cycles of contactors' of high-voltage battery module will soon reach its final value. |
| P1D27FB | Frequency counter 'Switching cycles of contactors' of high-voltage battery module will soon reach its final value. |
| P1D2800 | The frequency counter 'Switching cycles of contactors' of the high-voltage battery module has reached its final value. |
| P1D28FA | The frequency counter 'Switching cycles of contactors' of the high-voltage battery module has reached its final value. |
| P1D28FB | The frequency counter 'Switching cycles of contactors' of the high-voltage battery module has reached its final value. |
| P1D4BFA | The internal power supply of the control unit is implausible. |
| P1D4BFB | The internal power supply of the control unit is implausible. |
| P1D4BFC | The internal power supply of the control unit is implausible. |
| P1D4BFD | The internal power supply of the control unit is implausible. |
| P1DC200 | The limit value of the energy throughput at battery string A has been reached. |
| P1DC2FA | The limit value of the energy throughput at battery string A has been reached. |
| P1DC2FB | The limit value of the energy throughput at battery string A has been reached. |
| P1DC300 | The limit value of the energy throughput at battery string B has been reached. |
| P1DC3FA | The limit value of the energy throughput at battery string B has been reached. |
| P1DC3FB | The limit value of the energy throughput at battery string B has been reached. |
| P292800 | Contact 'Negative pole' of contactor B in the high-voltage battery is jammed open. |
| P292900 | Contact 'Negative terminal' of contactor B in the high-voltage battery is jammed closed. |
| P292A00 | The actuation of the contact 'Negative terminal' of contactor B in the hybrid/high-voltage battery has a short circuit to ground. |
| P292B00 | The actuation of the contact 'Negative terminal' of contactor B in the hybrid/high-voltage battery has a short circuit to positive. |
| P292BFA | The actuation of the contact 'Negative terminal' of contactor B in the hybrid/high-voltage battery has a short circuit to positive. |
| P292C00 | Contact 'Positive terminal' of contactor B in the high-voltage battery is jammed open. |
| P292D00 | Contact 'Positive terminal' of contactor B in the high-voltage battery is jammed closed. |
| P292E00 | The actuation of the contact 'Positive terminal' of contactor B in the hybrid/high-voltage battery has a short circuit to ground. |
| P292F00 | The actuation of the contact 'Positive terminal' of contactor B in the hybrid/high-voltage battery has a short circuit to positive. |
| P292FFA | The actuation of the contact 'Positive terminal' of contactor B in the hybrid/high-voltage battery has a short circuit to positive. |
| P293000 | The current of the high-voltage on-board electrical system at parallel string B is too high during precharging. |
| P293019 | The current of the high-voltage on-board electrical system at parallel string B is too high during precharging. The limit value for current has been exceeded. |
| P293098 | The current of the high-voltage on-board electrical system at parallel string B is too high during precharging. The component or the system has overtemperature. |
| P293100 | The precharging time at parallel string B of the high-voltage on-board electrical system is too long. |
| P2BC500 | The contact 'Positive terminal' of the contactor in the on-board DC current charge-connection unit is jammed closed. |
| P2BC600 | The contact 'Positive terminal' of the contactor in the on-board DC current charge-connection unit is jammed open. |
| P2BC700 | The contact 'Positive terminal' of the contactor in the on-board DC current charge-connection unit has an electrical fault or an open circuit. |
| P2BC900 | The actuation of the contact 'Positive terminal' of the contactor in the on-board DC current charge-connection unit has a short circuit to ground. |
| P2BCA00 | The actuation of the contact 'Positive terminal' of the contactor in the on-board DC current charge-connection unit has a short circuit to positive. |
| P2BCC00 | The contact 'Negative terminal' of the contactor in the on-board DC current charge-connection unit is jammed closed. |
| P2BCD00 | The contact 'Negative terminal' of the contactor in the on-board DC current charge-connection unit is jammed open. |
| P2BCE00 | The actuation of the contact 'Negative terminal' of the contactor in the on-board DC current charge-connection unit has an electrical fault or an open circuit. |
| P2BD000 | The actuation of the contact 'Negative terminal' of the contactor in the on-board DC current charge-connection unit has a short circuit to ground. |
| P2BD100 | The actuation of the contact 'Negative terminal' of the contactor in the on-board DC current charge-connection unit has a short circuit to positive. |
| P2BE402 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. There is a general signal fault. |
| P2BE4FA | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P2BE4FB | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P2BE4FC | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. |
| P2BE5FA | Sensor C for the battery current in the hybrid/high-voltage battery module has a malfunction. |
| P2BE5FB | Sensor C for the battery current in the hybrid/high-voltage battery module has a malfunction. |
| P2BE600 | Sensor C for the battery current in the hybrid/high-voltage battery module has a short circuit to ground. |
| P2BE6FA | Sensor C for the battery current in the hybrid/high-voltage battery module has a short circuit to ground. |
| P2BE6FB | Sensor C for the battery current in the hybrid/high-voltage battery module has a short circuit to ground. |
| P2BE700 | Sensor C for the battery current in the hybrid/high-voltage battery module has a short circuit to positive. |
| P2BE7FA | Sensor C for the battery current in the hybrid/high-voltage battery module has a short circuit to positive. |
| P2BE7FB | Sensor C for the battery current in the hybrid/high-voltage battery module has a short circuit to positive. |
| P2BE800 | The output for the switch 'Precharging' at battery string B of the hybrid/high-voltage battery module has an electrical fault or an open circuit. |
| P2BEA00 | The output for the switch 'Precharging' at battery string B of the hybrid/high-voltage battery module has a short circuit to ground. |
| P2BEB00 | The output for the switch 'Precharging' at battery string B of the hybrid/high-voltage battery module has a short circuit to positive. |
| P2C8500 | There is a vehicle-side insulation fault in the hybrid/high-voltage on-board electrical system. |
| P2C85FA | There is a vehicle-side insulation fault in the hybrid/high-voltage on-board electrical system. |
| P2C8600 | There is a battery-internal insulation warning in the hybrid/high-voltage battery module. |
| P2C86FA | There is a battery-internal insulation warning in the hybrid/high-voltage battery module. |
| P2C86FB | There is a battery-internal insulation warning in the hybrid/high-voltage battery module. |
| P2C8700 | There is a vehicle-side insulation warning in the hybrid/high-voltage on-board electrical system. |
| P2C8800 | There is an insulation warning in the hybrid/high-voltage on-board electrical system. |
| P2C8900 | The current of the high-voltage on-board electrical system at battery string A is too high during precharging. |
| P2C8919 | The current of the high-voltage on-board electrical system at battery string A is too high during precharging. The limit value for current has been exceeded. |
| P2C8998 | The current of the high-voltage on-board electrical system at battery string A is too high during precharging. The component or the system has overtemperature. |
| P2C8A00 | Sensor module A of the hybrid/high-voltage battery module has a malfunction. |
| P2C8A4B | Sensor module A of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| P2C8B00 | Sensor module B of the hybrid/high-voltage battery module has a malfunction. |
| P2C8B4B | Sensor module B of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| P2C9300 | The actuation of the contactors in the hybrid/high-voltage battery has a malfunction. |
| P2C9400 | The actuation of the contactors in the hybrid/high-voltage battery has a short circuit to ground. |
| P2C94FA | The actuation of the contactors in the hybrid/high-voltage battery has a short circuit to ground. |
| P2C9500 | The actuation of the contactors in the hybrid/high-voltage battery has a short circuit to positive. |
| P2C95FA | The actuation of the contactors in the hybrid/high-voltage battery has a short circuit to positive. |
| P2D3900 | Control unit 'Drivetrain' has triggered disconnection of the high-voltage on-board electrical system. |
| P2D39FA | Control unit 'Drivetrain' has triggered disconnection of the high-voltage on-board electrical system. |
| P2D3E00 | The hybrid/high-voltage battery has a malfunction during a cold start. |
| P2D4600 | Hybrid/high-voltage battery module B has overtemperature. |
| P2D46FA | Hybrid/high-voltage battery module B has overtemperature. |
| P2D46FB | Hybrid/high-voltage battery module B has overtemperature. |
| P2D46FC | Hybrid/high-voltage battery module B has overtemperature. |
| P2D46FD | Hybrid/high-voltage battery module B has overtemperature. |
| P2D46FE | Hybrid/high-voltage battery module B has overtemperature. |
| P2D46FF | Hybrid/high-voltage battery module B has overtemperature. |
| P2D4700 | Hybrid/high-voltage battery module C has overtemperature. |
| P2D4800 | Hybrid/high-voltage battery module D has overtemperature. |
| P2D4900 | Hybrid/high-voltage battery module E has overtemperature. |
| P2D4A00 | Hybrid/high-voltage battery module F has overtemperature. |
| P2D4B00 | Hybrid/high-voltage battery module G has overtemperature. |
| P2D4C00 | Hybrid/high-voltage battery module H has overtemperature. |
| P2D4D00 | Hybrid/high-voltage battery module I has overtemperature. |
| P2D4E00 | Hybrid/high-voltage battery module J has overtemperature. |
| P2D4F00 | Hybrid/high-voltage battery module K has overtemperature. |
| P2D5000 | Hybrid/high-voltage battery module L has overtemperature. |
| P2E3800 | The electric circuit for enabling the on-board DC charge-connection unit has a malfunction. |
| P2E6C00 | High-voltage battery module A has reached the limit value for cell thickness increase. |
| P2E6CFA | High-voltage battery module A has reached the limit value for cell thickness increase. |
| P2E6CFB | High-voltage battery module A has reached the limit value for cell thickness increase. |
| P2E6CFC | High-voltage battery module A has reached the limit value for cell thickness increase. |
| P2E6D00 | The sensor for cell thickness increase in high-voltage battery module A has a short circuit to positive. |
| P2E6DFA | The sensor for cell thickness increase in high-voltage battery module A has a short circuit to positive. |
| P2E6E00 | The sensor for cell thickness increase in high-voltage battery module A has a short circuit to ground. |
| P2E6EFA | The sensor for cell thickness increase in high-voltage battery module A has a short circuit to ground. |
| P2E6F00 | The sensor for cell thickness increase in high-voltage battery module A has a malfunction. |
| P2E6FFA | The sensor for cell thickness increase in high-voltage battery module A has a malfunction. |
| P2E7000 | High-voltage battery module B has reached the limit value for cell thickness increase. |
| P2E7100 | The sensor for cell thickness increase in high-voltage battery module B has a short circuit to positive. |
| P2E7200 | The sensor for cell thickness increase in high-voltage battery module B has a short circuit to ground. |
| P2E7300 | The sensor for cell thickness increase in high-voltage battery module B has a malfunction. |
| U007300 | Drive train CAN bus OFF fault |
| U007600 | Hybrid CAN bus OFF error |
| U010000 | Communication with the control unit 'combustion engine' has a malfunction. |
| U011500 | Communication with control unit 'Drivetrain' has a malfunction. |
| U011508 | Communication with control unit 'Drivetrain' has a malfunction. There is a signal fault or the message is faulty. |
| U0115FA | Communication with control unit 'Drivetrain' has a malfunction. |
| U0115FB | Communication with control unit 'Drivetrain' has a malfunction. |
| U014000 | Communication with the signal acquisition and actuation module has a malfunction. |
| U015500 | Communication with the instrument cluster has a malfunction. |
| U016800 | Communication with the electronic ignition lock has a malfunction. |
| U0168FA | Communication with the electronic ignition lock has a malfunction. |
| U019B00 | Communication with the on-board charger has a malfunction. |
| U01A000 | Internal communication of the hybrid/high-voltage battery module with sensor module A has a malfunction. |
| U01A0FA | Internal communication of the hybrid/high-voltage battery module with sensor module A has a malfunction. |
| U01A0FB | Internal communication of the hybrid/high-voltage battery module with sensor module A has a malfunction. |
| U01A100 | Internal communication of the hybrid/high-voltage battery module with sensor module B has a malfunction. |
| U01A200 | Internal communication of the hybrid/high-voltage battery module with sensor module C has a malfunction. |
| U01A300 | Internal communication of the hybrid/high-voltage battery module with sensor module D has a malfunction. |
| U01A400 | Internal communication of the hybrid/high-voltage battery module with sensor module E has a malfunction. |
| U01A500 | Internal communication of the hybrid/high-voltage battery module with sensor module F has a malfunction. |
| U01A800 | Internal communication of the hybrid/high-voltage battery module with sensor module I has a malfunction. |
| U01A900 | Internal communication of the hybrid/high-voltage battery module with sensor module J has a malfunction. |
| U01AA00 | Internal communication of the hybrid/high-voltage battery module with sensor module K has a malfunction. |
| U01AB00 | Internal communication of the hybrid/high-voltage battery module with sensor module L has a malfunction. |
| U01AC00 | Internal communication of the hybrid/high-voltage battery module with sensor module M has a malfunction. |
| U01AD00 | Internal communication of the hybrid/high-voltage battery module with sensor module N has a malfunction. |
| U01BB00 | Communication with the on-board DC current charge-connection unit has a malfunction. |
| U01BB08 | Communication with the on-board DC current charge-connection unit has a malfunction. There is a signal fault or the message is faulty. |
| U029800 | Communication with control unit ""DC/DC converter"" has a malfunction. |
| U030000 | An internal fault has occurred in the control unit software. |
| U0300FA | An internal fault has occurred in the control unit software. |
| U0300FB | An internal fault has occurred in the control unit software. |
| U0300FC | An internal fault has occurred in the control unit software. |
| U0300FD | An internal fault has occurred in the control unit software. |
| U0300FE | An internal fault has occurred in the control unit software. |
| U0300FF | An internal fault has occurred in the control unit software. |
| U033A00 | The software is incompatible with sensor module A in the high-voltage battery. |
| U033B00 | The software is incompatible with sensor module B in the high-voltage battery. |
| U033C00 | The software is incompatible with sensor module C in the high-voltage battery. |
| U033D00 | The software is incompatible with sensor module D in the high-voltage battery. |
| U033E00 | The software is incompatible with sensor module E in the high-voltage battery. |
| U033F00 | The software is incompatible with sensor module F in the high-voltage battery. |
| U034200 | The software is incompatible with sensor module I in the high-voltage battery. |
| U034300 | The software is incompatible with sensor module J in the high-voltage battery. |
| U034400 | The software is incompatible with sensor module K in the high-voltage battery. |
| U034500 | The software is incompatible with sensor module L in the high-voltage battery. |
| U034600 | The software is incompatible with sensor module M in the high-voltage battery. |
| U034700 | The software is incompatible with sensor module N in the high-voltage battery. |
| U034F00 | The software is incompatible with control unit 'Radiator shutters'. |
| U040100 | Implausible data were received from control unit 'combustion engine'. |
| U042300 | Implausible data were received from the instrument cluster. |
| U042700 | Implausible data were received from the electronic ignition lock. |
| U044200 | Implausible data were received from control unit 'Drivetrain'. |
| U0442FA | Implausible data were received from control unit 'Drivetrain'. |
| U0442FB | Implausible data were received from control unit 'Drivetrain'. |
| U049C00 | Implausible data were received from the on-board charger. |
| U04A1FA | Implausible data were received from sensor module A of the hybrid/high-voltage battery module. |
| U04A1FB | Implausible data were received from sensor module A of the hybrid/high-voltage battery module. |
| U04BE00 | Implausible data were received from the on-board DC current charge-connection unit. |
| U059900 | Implausible data were received from control unit ""DC/DC converter"". |
| U064A00 | Communication with current sensor A in the hybrid/high-voltage battery has a malfunction. |
| U064B00 | Communication with current sensor B in the hybrid/high-voltage battery has a malfunction. |
| U112081 | The security module of the control unit has detected a communication error. Incorrect data were received. |
| U112083 | The security module of the control unit has detected a communication error. The checksum for the message has an incorrect value. |
| U112087 | The security module of the control unit has detected a communication error. The message is missing. |
| U3001FA | The control unit was switched off improperly. |
| U3001FB | The control unit was switched off improperly. |
| U3001FC | The control unit was switched off improperly. |
| U301749 | The real-time internal control unit clock has a malfunction. There is an internal electrical fault. |
| U3017FA | The real-time internal control unit clock has a malfunction. |
| U3017FB | The real-time internal control unit clock has a malfunction. |
| U351200 | Interlock circuit B of the high-voltage on-board electrical system has a malfunction. |
| U357700 | Sensor module C of the hybrid/high-voltage battery module has a malfunction. |
| U35774B | Sensor module C of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| U357800 | Sensor module D of the hybrid/high-voltage battery module has a malfunction. |
| U35784B | Sensor module D of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| U357900 | Sensor module E of the hybrid/high-voltage battery module has a malfunction. |
| U35794B | Sensor module E of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| U357A00 | Sensor module F of the hybrid/high-voltage battery module has a malfunction. |
| U357A4B | Sensor module F of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| U357D00 | Sensor module I of the hybrid/high-voltage battery module has a malfunction. |
| U357D4B | Sensor module I of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| U357E00 | Sensor module J of the hybrid/high-voltage battery module has a malfunction. |
| U357E4B | Sensor module J of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| U357F00 | Sensor module K of the hybrid/high-voltage battery module has a malfunction. |
| U357F4B | Sensor module K of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| U358000 | Sensor module L of the hybrid/high-voltage battery module has a malfunction. |
| U35804B | Sensor module L of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| U358100 | Sensor module M of the hybrid/high-voltage battery module has a malfunction. |
| U35814B | Sensor module M of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| U358200 | Sensor module N of the hybrid/high-voltage battery module has a malfunction. |
| U35824B | Sensor module N of the hybrid/high-voltage battery module has a malfunction. There is a fault due to overtemperature. |