Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Mercedes Benz >> 2003 >> C32 >> Repair and Diagnosis >> Engine Performance >> Ignition System >> Mixture Formation -- Basic Knowledge -- 203 Chassis - 2 Of 2 >> Basic Knowledge >> ME-SFI start quantity control - function - GF07.61-P-3010SM

ME-SFI start quantity control - function - GF07.61-P-3010SM

ENGINE 113.986 

ENGINE 113.987 

ENGINE 113.988 

ENGINE 113.989 

Fig 1: ME-SFI Start Quantity Control Function - Engine 113.986/987/988/989
G04736830

In order to facilitate starting of a cold engine, additional fuel must be injected during the starting procedure, depending on the coolant temperature. The increased quantity of fuel (start quantity) injected is achieved by extending the injection time.

The start quantity control is dependent on:

The start quantity control is enabled after start recognition. It remains activated until a temperature-related engine speed is exceeded. The higher the coolant temperature, the lower is the start quantity metered by the ME-SFI control unit (N3/10).

  Component description for the fuel injection valves Y62 GF07.03-P-6010SM
  Component description for the crankshaft position sensor L5 GF07.04-P-6010SM
  Component description for the coolant temperature sensor B11/4 GF07.04-P-6040SM
  Component description for pressure sensor B28 GF07.04-P-6060SM
  Component description for the ME-SFI [ME] control unit N3/10 GF07.61-P-6000SM