Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Mercedes Benz >> 2000 >> ML430 >> Repair and Diagnosis >> Body & Frame >> Windows >> Windows - 163 Chassis >> Basic Knowledge >> Switching off after expiry of max. heating time, function - GF67.29-P-2003GI

Switching off after expiry of max. heating time, function - GF67.29-P-2003GI

MODEL 163 as of 1.12.99 

Function sequence 

The rear window defroster has a maximum switch-on time if it is not switched off manually by the rear window defroster switch (S21s9). The switch-on time depends on the outside temperature and the vehicle speed.

The outside temperature  is sensed by the temperature sensor (B14) and transmitted directly to the instrument cluster (A1). The instrument cluster (A1) stores the outside temperature value on the engine compartment CAN bus whereby it is available to the extended activity module (EAM)(N10/1).

The vehicle speed  is determined by the traction systems control module (N47) on the basis of the wheel speed and transmitted to the engine compartment CAN bus.

The switch-on time for the rear window defroster is determined in relation to the conditions listed above at the time the rear window defroster is switched on.

The following conditions and switch-on times are distinguished:

Switch-on time: 10 minutes

Switch-on time: 15 minutes

Switch-on time: 18 minutes

IMPORTANT If the voltage is too low  for 2 seconds while switching on, the heating current from the extended activity module (EAM)(N10/1) is interrupted and the rear window defroster indicator lamp (S21 e2) starts flashing. The switch-on time continues to expire. If the voltage is too low for more than 30 seconds the rear window defroster switches off completely and must be switched on again with the rear window defroster switch (S21 s9).

  Rear window defroster (RWD), function   GF67.29-P-0003GI 
  Rear window defroster (RWD), interlinkage of components   GF67.29-P-0003-02GI 
  Rear window defroster (RWD), location of components   GF67.29-P-0003-01GH 
  Switching on, function   GF67.29-P-2000GI 
  Switching off with switch, function   GF67.29-P-2002GI 
  Switching off with undervoltage, function   GF67.29-P-2005GI 
  Rear window defroster switch, location/purpose   GF67.29-P-3000GI 
  Rear window defroster relay, location/purpose   GF67.29-P-3001GI