REST button, function - GF83.40-P-2109-01A
Function
The residual engine heat utilization function can be switched on by pressing the residual engine heat utilization button (
) on the pushbutton control module. The system then operates automatically in the following states:
- Passenger compartment temperature depending on setting on temperature dials and display
- Blower low speed
- Flap position permanently programmed
- Battery voltage > 11.8 V
- Time limitation 30 minutes or ignition ON