DTC P011B:00 (PCM (SKYACTIV-G 2.0)) DETECTION CONDITION AND POSSIBLE CAUSE

DTC P011B:00 ECT/IAT: Correlation error
DETECTION CONDITION
  • Any one of the following conditions is met, the PCM detects a circuit/range performance problem:
    • The temperature detected by the ECT sensor after engine start(1) is 22°C {72°F} higher than the temperature detected by IAT sensor No. 1 20 s after engine start
    • The temperature detected by the ECT sensor after engine start(1) is a certain value lower than the temperature detected by IAT sensor No. 1 at engine start. (Without block heater)(2)

    MONITORING CONDITIONS 

  • The following conditions are met:
    • Period vehicle being left: 6 h or more
    • Battery voltage: 8 V or more
    • The following DTCs are not detected:
      • IAT sensor No. 1: P0110:00
      • ECT sensor: P0117:00, P0118:00

    Diagnostic support note 

  • This is a continuous monitor (CCM).
  • The check engine light illuminates if the PCM detects the above malfunction condition during the first drive cycle.
  • FREEZE FRAME DATA/Snapshot data is available.
  • DTC is stored in the PCM memory.
FAIL-SAFE FUNCTION
  • Not applicable
POSSIBLE CAUSE
  • ECT sensor connector or terminals malfunction
  • IAT sensor No. 1 connector or terminals malfunction
  • PCM connector or terminals malfunction
  • ECT sensor malfunction
  • IAT sensor No. 1 malfunction
  • PCM malfunction
SYSTEM WIRING DIAGRAM
  • Not applicable
(1) Ignition switch is ON when 6 h or more have passed since the ignition was switched off.

(2) Based on the output value from ECT sensor when the engine is started, if the input heat quantity required to increase the engine coolant temperature 3°C {5°F} exceeds the threshold, PCM determines that the block heater is equipped and does not determine a malfunction.