Line pressure
| Measurement conditions | Specification (kPa {kgf/cm2 , psi}) | |
|---|---|---|
| Idling | R position | 500 - 700 {5.10 - 7.13, 72.6 - 101.0} |
| D and M (1GR) position | 330 - 470 {3.37 - 4.79, 47.9 - 68.1} | |
| Stalling | R position | 1, 790 - 2, 100 {18.26 - 21.41, 259.7 - 304.5} |
| D and M (1GR) position | 970 - 1, 170 {9.90 - 11.93, 141.0 - 169.6} | |