  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  2. Discharge the refrigerant. (See REFRIGERANT RECOVERY .) (See REFRIGERANT CHARGING .)
  3. Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [VIN M] .)
  4. Disconnect the connector.
    G12188206Courtesy of MAZDA MOTORS CORP.
  5. Loosen the refrigerant pressure sensor using two spanners.
    G12188207Courtesy of MAZDA MOTORS CORP.
  6. Remove the refrigerant pressure sensor.
    G12188208Courtesy of MAZDA MOTORS CORP.
    CAUTION:
    • If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.
  7. Install in the reverse order of removal. (See Refrigerant pressure sensor installation note .)
  8. Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST .)