Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Mazda >> 2021 >> CX-3 AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 47 (On-Board Diagnostic - Body Control Module) >> DTC U2300-56: Configuration Data Unmatched With Instrument Cluster >> Diagnostic Procedure

Diagnostic Procedure

WARNING: This page is about a different car, the 2016 Mazda CX-3. However, it is still accessible from the selected car via links, so may be relevant.
Step Inspection Action
1 VERIFY BCM DTCs AGAIN 
Yes Go to the next step.
No Go to Step 5.
2 VERIFY INSTRUMENT CLUSTER DTCs 
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(Refer to DTC TABLE [INSTRUMENT CLUSTER] .)
No Go to the next step.
3 RESET CONFIGURATION DATA FROM INSTRUMENT CLUSTER TO BCM 
Yes Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again and wait for 30 s or more  .
(Refer to INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA) .)
Go to the next step.
No Go to Step 5.
4 VERIFY THAT REPAIRS HAVE BEEN COMPLETED 
Yes Replace the BCM, then go to the next step.
(Refer to BODY CONTROL MODULE (BCM) REMOVAL/INSTALLATION .)
No Go to the next step.
5 VERIFY IF OTHER DTCs DISPLAYED 
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(Refer to DTC TABLE [BCM] .)
No DTC troubleshooting completed.