DTC B1455:23 (POWER LIFTGATE CONTROL MODULE) DETECTION CONDITION AND POSSIBLE CAUSE

Description Power liftgate (PLG) touch sensor (RH) circuit malfunction
Detection Condition
  • Power liftgate (PLG) control module detected a short circuit to ground in the power liftgate (PLG) touch sensor (RH) circuit for 5 min or more.
Fail-safe
  • Stops the power liftgate (PLG) system operation.
Possible Cause
  • Power liftgate (PLG) touch sensor (RH) connector or terminal malfunction
  • Power liftgate (PLG) control module connector or terminal malfunction
  • Short to ground in wiring harness between power liftgate (PLG) touch sensor (RH) terminal B and power liftgate (PLG) control module terminal 1P
  • Power liftgate (PLG) touch sensor (RH) malfunction
  • Power liftgate (PLG) control module malfunction