Description Configuration data unmatched with instrument cluster
Detection condition 
  • Configuration data of the blind spot monitoring (BSM) control module and instrument cluster are not matched with the ignition switched ON (engine off or on).
Fail-safe 
  • Blind spot monitoring (BSM) system is stopped.
Possible cause 
NOTE:
  • To correctly write the configuration data sent from the instrument cluster to the blind spot monitoring (BSM) control module (LH) to the blind spot monitoring (BSM) control module (LH), 30 s or more  need to have elapsed since the ignition was switched ON (engine off or on).
  • DTCs are stored in the instrument cluster.
    • Instrument cluster configuration not implemented
    • Instrument cluster internal memory malfunction
  • Instrument cluster configuration data error
  • Blind spot monitoring (BSM) control module (LH) malfunction
System wiring diagram  Not applicable