Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Mazda >> 2014 >> 3 SV, Automatic Trans >> Repair and Diagnosis >> Engine Performance >> System >> On-Board Diagnostic - Engine Controls (3 Of 6) >> DTC P0532 00: Refrigerant Pressure Sensor Circuit Low Input >> Diagnostic Procedure

Diagnostic Procedure

DTC P0532:00 (SKYACTIV-G 2.0, SKYACTIV-G 2.5) - DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 VERIFY RELATED REPAIR INFORMATION AVAILABILITY 
  • Verify related Service Bulletins and/or on-line repair information availability.
  • Is any related repair information available?
Yes Perform repair or diagnosis according to the available repair information.
  • If the vehicle is not repaired, go to the next step.
No Go to the next step.
2 INSPECT REFRIGERANT PRESSURE SENSOR CONNECTOR CONDITION 
  • Switch the ignition off.
  • Disconnect the refrigerant pressure sensor connector.
  • Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
  • Is there any malfunction?
Yes Repair or replace the connector and/or terminals, then go to Step 8.
No Go to the next step.
3 INSPECT REFRIGERANT PRESSURE SENSOR CIRCUIT FOR SHORT TO GROUND 
  • Verify that the refrigerant pressure sensor connector is disconnected.
  • Inspect for continuity between the following terminals (wiring harness-side) and body ground:
    • Refrigerant pressure sensor terminal A
    • Refrigerant pressure sensor terminal B
  • Is there continuity?
Yes If the short to ground circuit could be detected in the wiring harness:
  • Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
    • Refrigerant pressure sensor terminal A-PCM terminal 2BB
    • Refrigerant pressure sensor terminal B-PCM terminal 2AX

    If there is a common connector: 

    • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
    • Repair or replace the malfunctioning part.

    If there is no common connector: 

    • Repair or replace the wiring harness which has a short to ground.

If the short to ground circuit could not be detected in the wiring harness:

Go to Step 8.
No Go to the next step.
4 INSPECT PCM CONNECTOR CONDITION 
  • Disconnect the PCM connector.
  • Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
  • Is there any malfunction?
Yes Repair or replace the connector and/or terminals, then go to Step 8.
No Go to the next step.
5 INSPECT REFRIGERANT PRESSURE SENSOR SIGNAL CIRCUIT AND GROUND CIRCUIT FOR SHORT TO EACH OTHER 
  • Verify that the refrigerant pressure sensor and PCM connectors are disconnected.
  • Inspect for continuity between refrigerant pressure sensor terminals B and C (wiring harness-side).
  • Is there continuity?
Yes Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
  • Refrigerant pressure sensor terminal B-PCM terminal 2AX
  • Refrigerant pressure sensor terminal C-PCM terminal 2AJ

If there is a common connector: 
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to each other.
  • Repair or replace the malfunctioning part.

If there is no common connector: 
  • Repair or replace the wiring harness which has a short to each other.

Go to Step 8.
No Go to the next step.
6 INSPECT REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT 
  • Verify that the refrigerant pressure sensor and PCM connectors are disconnected.
  • Inspect for continuity between refrigerant pressure sensor terminal A (wiring harness-side) and PCM terminal 2BB (wiring harness-side).
  • Is there continuity?
Yes Go to the next step.
No Refer to the wiring diagram and verify whether or not there is a common connector between refrigerant pressure sensor terminal A and PCM terminal 2BB.
If there is a common connector: 
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
  • Repair or replace the malfunctioning part.

If there is no common connector: 
  • Repair or replace the wiring harness which has an open circuit.

Go to Step 8.
7 INSPECT REFRIGERANT PRESSURE SENSOR 
Yes Replace the refrigerant pressure sensor, then go to the next step.
(See REFRIGERANT PRESSURE SENSOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER] .)
(See REFRIGERANT PRESSURE SENSOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER] .)
No Go to the next step.
8 VERIFY DTC TROUBLESHOOTING COMPLETED 
Yes Repeat the inspection from Step 1.

Go to the next step.
No Go to the next step.
9 VERIFY AFTER REPAIR PROCEDURE 
Yes Go to the applicable DTC inspection.
(See DTC TABLE [SKYACTIV-G 2.0, SKYACTIV-G 2.5] .)
No DTC troubleshooting completed.