Home >> Mazda >> 2012 >> 6 i Touring Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 569 (On-Board Diagnostic [Immobilizer System (Advanced Keyless Entry And Push Button Start System))) >> Security Light: 14, DTC: B10D7:81/P1260:00 [Immobilizer System (Advanced Keyless Entry And Push Button Start System)] >> Notes

Security Light: 14, DTC: B10D7:81/P1260:00 [Immobilizer System (Advanced Keyless Entry And Push Button Start System)]: Notes

WARNING: This page is about a different car, the 2009 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
B10D7:81/P1260:00 REFERENCE

DTC Security light flashing pattern 14 Keyless control module cannot read key ID number data normally
M-MDS display Keyless control module B10D7:81
PCM P1260:00
POSSIBLE CAUSE
  • Connector or terminal malfunction
  • Transponder (key) malfunction
  • If any of the following items are touching or near key head, signal communication between key and vehicle is negatively affected, resulting in engine not starting:
    • Spare keys

EXAMPLES:
G06200529Courtesy of MAZDA MOTORS CORP.

  • Keys for other vehicles equipped with an immobilizer system
  • Any metallic object
  • Any electronic device, or any credit or other card with magnetic strips

  • Coil antenna malfunction
  • PCM malfunction
  • Keyless control module malfunction