After engine start, electrical devices do not operate 
DESCRIPTION 
  • Possible cause related to non-operation of electrical devices (such as blower motor, rear wiper) with ignition switched to ignition to ON (IG2), after engine start.
Possible Causes 
  • Open or short circuit in wiring harness between battery and relay block (IG2 relay) and each part
  • Fuse burnt out (short to ground in related wiring harness)
  • Open circuit in wiring harness between keyless control module and relay block (IG2 relay)
  • Relay block (IG2 relay) malfunction (stuck open)
  • Keyless control module malfunction
NOTE:
  • Even if the advanced key is inside the vehicle, the advanced start function may not operate if the advanced key is in a poor signal reception location such as the door pocket.
DIAGNOSTIC PROCEDURE

Step Inspection Action
1
  • Do the electrical devices operate with the ignition is switched to ACC, ignition to ON (IG1)?
Yes Go to the next step.
No Go to symptom troubleshooting procedure "No. 3 Push button start does not operate".
2
  • Disconnect the keyless control module connector.
  • Connect battery positive voltage to the following connector terminal on the keyless control module vehicle wiring harness side.
    • Terminal 3G (IG2)
  • Measure the voltage of the following connector terminal on the keyless control module vehicle wiring harness side.
    • Terminal 2E (IG2)
  • Is the voltage B+?
Yes Replace the keyless control module.
(See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION ).
After replacement, go to Step 7.
No Go to the next step.
3
  • Leave the keyless control module connector disconnected.
  • Disconnect the relay block connector.
  • Verify the continuity between the following connector terminals on the vehicle wiring harness side:
    • Between keyless control module terminal 2E and relay block terminal 1C (6-pin) (IG2 monitor).
    • Between keyless control module terminal 3G and relay block terminal 2A (8-pin) (IG2 relay primary power supply).
  • Can continuity be verified?
Yes Go to the next step.
No After repairing for an open circuit in the wiring harness, go to Step 7.
4
  • Leave the relay block connector disconnected.
  • Verify the continuity between connector terminal 2C (8-pin) on the relay block vehicle wiring harness side and ground.
  • Can continuity be verified?
Yes Go to the next step.
No Repair for an open circuit in the wiring harness.
Inspect and repair the ground point.
After repair procedure, go to Step 7.
5
  • Leave the relay block connector disconnected.
  • Measure the voltage of connector terminal 1A (6-pin) and terminal 1E (6-pin) on the relay block vehicle wiring harness side.
  • Is the voltage B+?
Yes Go to the next step.
No After repairing for an open circuit in the wiring harness, go to Step 7.
6 Yes
No Replace the relay block, then go to the next step.
7
  • Do the electrical devices (such as blower motor, rear wiper) operate normally after starting the engine?
Yes Troubleshooting completed.
Explain the contents of the servicing to the customer.