Variable Fresh Air Duct (VFAD) Control System Operation Inspection
- Connect the M-MDS to the DLC-2.
- Access the RPM PID.
- Start the engine.
- Inspect shutter valve operation under the following conditions.
VFAD shutter valve operation
VFAD SHUTTER VALVE OPERATION REFERENCE CHARTEngine speed 5,250 RPM Below Above Shutter valve Close Open - If the shutter valve operation is not as specified, inspect VFAD solenoid valve. (See
VARIABLE FRESH AIR DUCT (VFAD) SOLENOID VALVE INSPECTION [13B-MSP]
.)
- If the VFAD solenoid valve is not normal, replace VFAD solenoid valve.
- If the VFAD solenoid valve is normal, inspect the following:
- Open or short circuit PCM terminal 1AE and VFAD solenoid valve terminal B
- Open or short circuit main relay and VFAD solenoid valve terminal B
- Vacuum hose looseness or damage
- Vacuum chamber cracked or damaged
- Shutter valve actuator
(See VARIABLE FRESH AIR DUCT (VFAD) ACTUATOR INSPECTION [13B-MSP] .)
- Shutter valve is stuck open or closed.
- If the shutter valve operation is not as specified, inspect VFAD solenoid valve. (See
VARIABLE FRESH AIR DUCT (VFAD) SOLENOID VALVE INSPECTION [13B-MSP]
.)