Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Mazda >> 2010 >> 3 Mazdaspeed, 2.3 4 >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Symptom Troubleshooting [Advanced Keyless Entry And Push Button Start System] >> No. 4 After Engine Start, Electrical Devices Do Not Operate [Advanced Keyless Entry And Push Button Start System] >> Diagnostic Procedure

Diagnostic Procedure

DIAGNOSTIC PROCEDURE

Step Inspection Action
1
  • Do the electrical devices operate with the ignition is switched to ACC, ignition to ON (IG1)?
Yes Go to the next step.
No Go to NO. 3 PUSH BUTTON START SYSTEM DOES NOT OPERATE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM]  .
2
  • Disconnect the keyless control module connector.
  • Connect battery positive voltage to the following connector terminal on the keyless control module vehicle wiring harness side.
    • Terminal 3G (IG2)
  • Measure the voltage of the following connector terminal on the keyless control module vehicle wiring harness side.
    • Terminal 2E (IG2)
  • Is the voltage B+?
Yes Replace the keyless control module.
(See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION .)
After replacement, go to Step 7.
No Go to the next step.
3
  • Leave the keyless control module connector disconnected.
  • Disconnect the relay block connector.
  • Verify the continuity between the following connector terminals on the vehicle wiring harness side:
    • Between keyless control module terminal 2E and relay block terminal 1C (6-pin) (IG2 monitor).
    • Between keyless control module terminal 3G and relay block terminal 2A (8-pin) (IG2 relay primary power supply).
  • Can continuity be verified?
Yes Go to the next step.
No After repairing for an open circuit in the wiring harness, go to Step 7.
4
  • Leave the relay block connector disconnected.
  • Verify the continuity between connector terminal 2C (8-pin) on the relay block vehicle wiring harness side and ground.
  • Can continuity be verified?
Yes Go to the next step.
No Repair for an open circuit in the wiring harness.
Inspect and repair the ground point.
After repair procedure, go to Step 7.
5
  • Leave the relay block connector disconnected.
  • Measure the voltage of connector terminal 1A (6-pin) and terminal 1E (6-pin) on the relay block vehicle wiring harness side.
  • Is the voltage B+?
Yes Go to the next step.
No After repairing for an open circuit in the wiring harness, go to Step 7.
6 Yes
No Replace the relay block, then go to the next step.
7
  • Do the electrical devices (such as blower motor, rear wiper) operate normally after starting the engine?
Yes Troubleshooting completed.
Explain the contents of the servicing to the customer.
No If the malfunction has not been resolved, repeat the inspection from Step 1.