DTC B10E7:11 (ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM) DETECTION CONDITION AND POSSIBLE CAUSE

DESCRIPTION Short to ground in IG1 relay circuit
DETECTION CONDITION 
  • IG1 relay output monitor is off for 0.5 s when the ignition switch is ON.
POSSIBLE CAUSE 
  • Relay block connector or terminals malfunction
  • Keyless control module connector or terminals malfunction
  • Short to ground in wiring harness between the following terminals:
    • Relay block terminal 2G-Keyless control module terminal 3D
  • Relay block malfunction
  • Keyless control module malfunction
G06731457Courtesy of MAZDA MOTORS CORP.