Diagnostic Procedure
CAUTION:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
DIAGNOSIS PROCEDURE
| PINPOINT TEST 8 | THE TRANSMISSION CONTROL MODULE (TCM) DOES NOT RESPOND TO THE SCAN TOOL - HYBRID | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK THE POWER TO THE TCM
|
Yes | GO to the next step. |
| No | VERIFY the battery junction box (BJB) fuse 27 (10A) or fuse 8 (5A) is OK. If OK, REPAIR the circuit in question. CLEAR the DTCs. REPEAT the network test with the scan tool. | ||
| 2 | CHECK THE TCM GROUNDS
|
Yes | GO to the next step. |
| No | REPAIR the circuit in question. CLEAR the DTCs. REPEAT the network test with the scan tool. | ||
| 3 | CHECK THE HS-CAN CIRCUITS BETWEEN THE TCM AND THE DATA LINK CONNECTOR (DLC) FOR AN OPEN
|
Yes | GO to next step. |
| No | REPAIR the circuit in question. CLEAR the DTCs. REPEAT the network test with the scan tool. | ||
| 4 | CHECK FOR CORRECT TCM OPERATION
|
Yes | INSTALL a new TCM. CLEAR the DTCs. REPEAT the network test with the scan tool. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the network test with the scan tool. | ||