Diagnostic Procedure
CAUTION:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
DIAGNOSIS PROCEDURE
| PINPOINT TEST 12 | THE DUAL AUTOMATIC TEMPERATURE CONTROL (DATC) MODULE DOES NOT RESPOND TO THE SCAN TOOL - HYBRID | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK THE DATC MODULE VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
|
Yes | GO to the next step. |
| No | VERIFY the smart junction box (SJB) fuse 15 (10A) or fuse 37 (10A) is OK. If OK, REPAIR the circuit in question. CLEAR the DTCs. REPEAT the network test with the scan tool. | ||
| 2 | CHECK THE DATC MODULE GROUND CIRCUIT FOR AN OPEN
|
Yes | GO to the next step. |
| No | REPAIR the circuit. CLEAR the DTCs. REPEAT the network test with the scan tool. | ||
| 3 | CHECK THE MS-CAN CIRCUITS BETWEEN THE DATC MODULE AND THE DATA LINK CONNECTOR (DLC) FOR AN OPEN
|
Yes | GO to the next step. |
| No | REPAIR the circuit in question. CLEAR the DTCs. REPEAT the network test with the scan tool. | ||
| 4 | CHECK FOR CORRECT DATC MODULE OPERATION
|
Yes | INSTALL a new DATC module. See CLIMATE CONTROL MODULE REMOVAL/INSTALLATION . CLEAR the DTCs. REPEAT the network test with the scan tool. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the network test with the scan tool. | ||