Step 1
- With the engine stopped, depress the pedal a few times.
- With the pedal depressed, start the engine.
- If the pedal moves down slightly, immediately after engine starts, the unit is operating.
- If not, inspect for damage on the check valve or vacuum hose, and examine the installation. Repair if necessary, and inspect it again.