Refrigerant Pressure Switch Inspection
- Install the manifold gauge set. (See MANIFOLD GAUGE SET INSTALLATION .)
- Disconnect the refrigerant pressure switch connector.
- Verify the high-pressure side reading of the manifold gauge and continuity between the terminals B and C, and A and D is as shown.
- If not as specified, replace the front cooler pipe No. 2.
Courtesy of MAZDA MOTORS CORP.
- If not as specified, replace the front cooler pipe No. 2.