Detection Condition
The PCM monitors Mass Airflow/Intake Air Temperature (MAF/IAT) sensor signal at PCM 30-pin harness connector terminal "2E" (Blue/Black wire). If PCM detected MAF/IAT sensor voltage more than 4.84 volts, PCM determines MAF/IAT signal circuit has malfunction. This is a Continuous Monitor (CM). MIL illuminates if PCM detects malfunction condition during first drive cycle. PENDING CODE is available if PCM detects malfunction condition. FREEZE FRAME DATA is available. DTC is stored in PCM memory.