  1. Disconnect the negative battery cable.
  2. Remove the column cover.
  3. Disconnect the connector.
  4. Inspect the continuity.
    • If not as specified, replace selector lever. (See SELECTOR LEVER REMOVAL/INSTALLATION .)
      Fig 1: P Position Switch Continuity Specifications
      G00993738Courtesy of MAZDA MOTORS CORP.
      Fig 2: Identifying P Position Switch Side Connector Terminals
      G00993739Courtesy of MAZDA MOTORS CORP.
  5. Connect the connector.
  6. Install the column cover.
  7. Connect the negative battery cable.