Pinpoint Test Z : The GFM2 (Generic Function Module 2) Does Not Respond To The Scan Tool
WARNING: This page is about a different car, the 2018 Ford Focus. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Failure to disconnect the battery when instructed will result in false resistance readings.
- Z1 CHECK THE GFM2 (GENERIC FUNCTION MODULE 2) VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: GFM2 C3719 .
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C3719-1 Ground
Are the voltages greater than 11 volts?
Yes GO to Z2 No VERIFY RJB fuse 39 (15A) is OK. If OK, REPAIR the circuit in question. If not OK, REFER to the OEM ELECTRICAL WIRING DIAGRAM INTRODUCTION (EXCEPT ELECTRIC) to identify the possible causes of the circuit short. - Z2 CHECK THE GFM2 (GENERIC FUNCTION MODULE 2) GROUND CIRCUIT FOR AN OPEN
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead C3719-13 Ground
Are the resistances less than 3 ohms?
Yes GO to Z3 No REPAIR the circuit in question. - Z3 CHECK THE HS-CAN (HIGH-SPEED CONTROLLER AREA NETWORK) CIRCUITS BETWEEN THE GFM2 (GENERIC FUNCTION MODULE 2) AND THE DLC (DATA LINK CONNECTOR) FOR AN OPEN
Are the resistances less than 3 ohms?
Yes GO to Z4 No REPAIR the circuit in question. - Z4 CHECK FOR CORRECT GFM2 (GENERIC FUNCTION MODULE 2) OPERATION
- Ignition OFF.
- Disconnect and inspect all the GFM2 connectors and related in-line connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the GFM2 connectors and related in-line connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new GFM2. No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.