Manifold Gauge Set Connection

SPECIAL TOOLS DESCRIPTION

G04692061Courtesy of FORD MOTOR CO.
R-134a Manifold Gauge Set
176-R032A or equivalent
  1. Turn both valves on the R-134a Manifold Gauge Set clockwise to close the low-and high-pressure hoses to the center manifold and center hose.
    Fig 1: Locating R-134A Manifold Gauge Set Valves
    G04692062Courtesy of FORD MOTOR CO.
  2. Remove the A/C charging valve cap from the high-pressure service gauge port valve.
    Fig 2: Removing A/C Charging Valve Cap From High-Pressure Service Gauge Port Valve
    G04692063Courtesy of FORD MOTOR CO.
  3. Connect the R-134a Manifold Gauge Set high-pressure hose and the R-134a high side quick disconnect to the high-pressure service gauge port valve.
    Fig 3: Connecting R-134A Manifold Gauge Set High-Pressure Hose To High-Pressure Service Gauge Port Valve
    G04692064Courtesy of FORD MOTOR CO.
  4. Raise the vehicle. For additional information, refer to JACKING AND LIFTING .
  5. Remove the screws and the left sight shield.
    Fig 4: Removing Left Sight Shield
    G04692065Courtesy of FORD MOTOR CO.
  6. Remove the A/C charging valve cap from the low-pressure service gauge port valve.
    Fig 5: Removing A/C Charging Valve Cap From Low-Pressure Service Gauge Port Valve
    G04692066Courtesy of FORD MOTOR CO.
  7. Connect the R-134a Manifold Gauge Set low-pressure hose and the R-134a low side quick disconnect to the low-pressure service gauge port valve.
    Fig 6: Connect R-134A Manifold Gauge Set Low-Pressure Hose To Low-Pressure Service Gauge Port Valve
    G04692067Courtesy of FORD MOTOR CO.
  8. To disconnect the manifold and gauge set, reverse the connection procedure.