Crank Signal Not Within Limits
- Using DVOM, test battery voltage (10.5 volts minimum). Recharge, repair or replace battery as required and retest.
- Disconnect harness wire from "S" terminal on starter relay and set test selector switch to position "22". With ignition switch in "START" position, verify that reading is 5.0 volts or more.
- If reading is less than 5.0 volts, check for open or short circuits in Black Wire and/or Red/Light Blue wire. See Figure. Repair wire(s) and retest. Reconnect harness wire to "S" terminal of starter relay.