Hybrid Battery System
HYBRID BATTERY SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION
| DTC Code | Description |
|---|---|
| P0560-14 | System Voltage (BATT) Circuit Short to Ground or Open |
| P0606-29 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid |
| P0606-87 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message |
| P060A-47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A-87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message |
| P060B-16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold |
| P060B-49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure |
| P062F-44 | Hybrid/EV Battery Energy Control Module EEPROM Data Memory Failure |
| P062F-46 | Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure |
| P0A1D-94 | Hybrid/EV Powertrain Control Module Unexpected Operation |
| P0A81-00 | Hybrid/EV Battery Cooling Fan 1 Control Circuit High |
| P0A81-11 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground |
| P0A81-15 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open |
| P0A81-4B | Hybrid/EV Battery Cooling Fan 1 Over Temperature |
| P0A81-96 | Hybrid/EV Battery Cooling Fan 1 Component Internal Failure |
| P0A81-98 | Hybrid/EV Battery Cooling Fan 1 Component or System Over Temperature |
| P0A95-63 | High Voltage Fuse Accumulated Load History |
| P0A9B-11 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground |
| P0A9B-15 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0A9B-1C | Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range |
| P0A9B-2A | Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range |
| P0AAC-11 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground |
| P0AAC-15 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0ABF-11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground |
| P0ABF-15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0ABF-28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0ABF-2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range |
| P0AC5-11 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground |
| P0AC5-15 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0AC5-1C | Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range |
| P0AC5-2A | Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range |
| P0ACA-11 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground |
| P0ACA-15 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P0ACA-1C | Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range |
| P0ACA-2A | Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range |
| P0AE8-11 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground |
| P0AE8-15 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open |
| P0AE8-1C | Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range |
| P0AE8-2A | Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range |
| P0B0E-11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground |
| P0B0E-15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0B13-62 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure |
| P0BC2-11 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground |
| P0BC2-15 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open |
| P0BC2-1C | Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range |
| P0BC2-2A | Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range |
| P0C30-00 | Hybrid/EV Battery State of Charge High |
| P0C33-11 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground |
| P0C33-15 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open |
| P0C33-1C | Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range |
| P0C33-2A | Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range |
| P0E2D-00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance |
| P1A00-1C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range |
| P1A60-17 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold |
| P1A61-16 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold |
| P1A80-00 | Hybrid/EV Battery Stack 1 Delta SOC High |
| P1A81-00 | Hybrid/EV Battery Stack 1 Delta SOC High (Extreme) |
| P1A85-00 | Hybrid/EV Battery Stack 2 Delta SOC High |
| P1A86-00 | Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) |
| P1AFC-00 | System Voltage (AM) Circuit Voltage Below Threshold |
| P1AFD-00 | Flying Capacitor Circuit Voltage Out of Range |
| P1AFD-1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range |
| P1AFF-00 | Hybrid/EV Battery ECU Multiple Reset |
| P1C85-49 | High Voltage Power Resource Internal Electronic Failure |
| P1C9F-11 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground |
| P1C9F-15 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open |
| P1C9F-1C | Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range |
| P1CBB-12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery |
| P1CBB-14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open |
| P1CC8-1E | Hybrid/EV Battery Stack 1 Voltage Difference Out of Range |
| P1CC9-1E | Hybrid/EV Battery Stack 2 Voltage Difference Out of Range |
| P3000-00 | Hybrid/EV Battery Discharge Control Malfunction |
| P3000-16 | Hybrid/EV Battery Control System Circuit Voltage Below Threshold |
| P3000-4B | Hybrid/EV Battery Control System Over Temperature |
| P301A-1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range |
| P3065-62 | Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure |
| P306A-62 | Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure |
| P31AA-17 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold |
| P31AB-16 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold |
| P31B3-00 | Hybrid/EV Battery Voltage High |
| P31B4-00 | Extreme Hybrid/EV Battery Charging Current |
| P31B5-49 | Hybrid/EV Battery Internal Electronic Failure |
| P33DA-1E | Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range |
| P33DB-1E | Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range |
| P33E0-1B | Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold |
| P33E1-1B | Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold |
| P33EC-16 | (Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold |
| P33ED-16 | (Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold |
| U0100-87 | Lost Communication with ECM/PCM "A" Missing Message |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U1150-87 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |