Inspection [10/2014 - ]: Procedure
- INSPECT FUEL DELIVERY PIPE (FUEL PRESSURE SENSOR) NOTE:
- Do not remove the fuel pressure sensor from the fuel delivery pipe sub-assembly.
- If a fuel pressure sensor is removed, replace the fuel delivery pipe sub-assembly (fuel pressure sensor) with a new one.
- Check the fuel pressure sensor output voltage.
- Apply 5 V between terminals 1 (VC) and 3 (E2).
*a Component without harness connected
(Fuel Pressure Sensor)*b Voltage applied between terminals NOTE:- Be careful when connecting the leads, as the fuel pressure sensor may be damaged if the leads are connected to the wrong terminals.
- Do not apply more than 6 V to terminals 1 (VC) and 3 (E2).
HINT:
If a stable power supply is not available, use 4 1.2 V nickel-metal hydride batteries or equivalent.
- Apply 5 V between terminals 1 (VC) and 3 (E2).
- Measure the voltage between terminals.
Standard Voltage
Tester Connection Condition Specified Condition 2 (PFL) - 3 (E2) Pressure not applied to fuel pressure sensor Approximately 0.6 to 0.9 V If the result is not as specified, replace the fuel delivery pipe (fuel pressure sensor).
*a Component without harness connected
(Fuel Pressure Sensor)