Inspection [09/2015 - ]: Procedure
- INSPECT HEIGHT CONTROL COMPRESSOR (EXHAUST VALVE)
- Measure the resistance of the exhaust valve.
- Check the exhaust valve operation.
- INSPECT HEIGHT CONTROL COMPRESSOR (COMPRESSOR MOTOR)
- Check the compressor operation.
- Connect terminal 1 (B) to the battery positive (+) terminal, and terminal 2 (E) to the battery negative (-) terminal.
- Check the operation of the compressor motor.
OK
Motor operates.
TEXT IN ILLUSTRATION*a Component without harness connected
(Height Control Compressor)NOTE:- Do not operate the height control compressor for 60 seconds or more.
- Since a short and a lock-up inside the height control compressor cause excessive current to flow, stop operation immediately when the compressor motor does not operate.