DTC B2272: Ignition 1 Monitor Malfunction: Procedure
- READ VALUE USING THE TECHSTREAM (IG1 RELAY MONITOR (OUTSIDE))
- Use the Data List to check if the D-IG1 relay is functioning properly.MAIN BODY
Tester Display Measurement Item/Range Normal Condition Diagnostic Note IG1 Relay Monitor (Outside) D-IG1 relay outer relay monitor/ON or OFF ON: Power switch ON (IG)
OFF: Power switch OFF- OK
When the power switch is turned ON (IG), ON is displayed on the Techstream screen.
NG → See step 3
OK: Go to next step
- Use the Data List to check if the D-IG1 relay is functioning properly.
- CHECK POWER SWITCH (SWITCH CONDITION)
- Ensure the key is inside the cabin.
- With the brake pedal released, check that the power source mode changes as shown below each time the power switch is pushed.
OK
OFF → ON (ACC) → ON (IG) → OFF
NG → See step 4
OK → See step 5
- CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - BATTERY, BODY GROUND)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Disconnect the L13, DF and DA main body ECU connectors.
- Measure the voltage and resistance according to the value(s) in the table below.
Standard voltage
Tester Connection Condition Specified Condition DF-1 - Body ground Always 11 to 14 V Standard resistance
Tester Connection Condition Specified Condition L13-3 (IG1D) - DA-32 Always Below 1 Ω DA-40 (GND1) - Body ground Always Below 1 Ω L13-3 (IG1D) or DA-32 - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → REPLACE MAIN BODY ECU
- GO TO SMART ACCESS SYSTEM WITH PUSH-BUTTON START (POWER SOURCE MODE DOES NOT CHANGE). Refer to Power Source Mode does not Change
- USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING