Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Lexus >> 2011 >> LS 600hL >> Repair and Diagnosis >> Electrical >> Starter >> Smart Access System With Push-Button Start (Keyless Start) (Diagnostic Codes & Symptom Tests) >> Smart Access System With Push-Button Start >> DTC B2271: Ignition Hold Monitor Malfunction >> Procedure

DTC B2271: Ignition Hold Monitor Malfunction: Procedure

  1. CHECK WHETHER DTC OUTPUT RECURS 
    1. Clear the DTCs. Refer to DTC CHECK / CLEAR .
    2. Check whether DTC B2271 recurs.
      RESULT

      Display (DTC output) Proceed to
      B2271 A
      No DTC output B

    B → See step   4 

    A: Go to next step 

  2. INSPECT FUSE (AM2) 
    1. Remove the AM2 fuse from the passenger side junction block.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance

      Tester Connection Condition Specified Condition
      AM2 fuse Always Below 1 Ω

    NG → REPLACE FUSE 

    OK: Go to next step 

  3. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - BATTERY, BODY GROUND) 
    Fig 1: Identifying Main Body ECU Connector Terminal Identification
    GTY109978Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Disconnect the L13, L12 and DA main body ECU connectors.
    2. Measure the voltage and resistance according to the value(s) in the table below.

      Standard voltage

      Tester Connection Condition Specified Condition
      L13-6 (AM1) - Body ground Always 11 to 14 V
      L12-1 (AM2) - Body ground Always 11 to 14 V

      Standard resistance

      Tester Connection Condition Specified Condition
      DA-40 (GND1) - Body ground Always Below 1 Ω

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → REPLACE MAIN BODY ECU 

  4. USE SIMULATION METHOD TO CHECK. Refer to  HOW TO PROCEED WITH TROUBLESHOOTING