Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Lexus >> 2008 >> LS 460L >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning >> PTC Heater Assembly >> Inspection

PTC Heater Assembly: Inspection

  1. INSPECT PTC HEATER ASSEMBLY 
    1. Measure the resistance according to the value (s) in the table below.

      Standard Resistance 

      RESISTANCE REFERENCE

      Tester Connection Condition Specified Condition
      A-1 - B-1 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω
      A-2 - B-1 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω
      A-2 - B-2 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω
      A-3 - B-2 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω

      If the result is not as specified, replace the PTC heater assembly.

      Fig 1: Identifying PTC Heater Connector Terminals
      G04950671Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002