  1. INSPECT FUSE (D-IG1-3) 
    1. Remove the D-IG1-3 fuse from the driver side junction block.
    2. Measure the resistance of the fuse.

      Standard resistance 

      FUSE (D-IG1-3)

      Tester Connection Condition Specified Condition
      D-IG1-3fuse Always Below 1 Ω

    NG: REPLACE FUSE 

    OK: GO TO NEXT STEP 

  2. CHECK HARNESS AND CONNECTOR (INFRARED RAY SENSOR - BODY GROUND AND BATTERY) 
    Fig 1: Checking Harness And Connector (Infrared Ray Sensor - Body Ground And Battery)
    G04950445Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Disconnect the X13 infrared ray sensor connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      INFRARED RAY SENSOR - BODY GROUND AND BATTERY RESISTANCE

      Tester Connection Condition Specified Condition
      X13-1 (E) - Body ground Always 10 kΩ or higher
    3. Measure the voltage according to the value(s) in the table below.

      Standard voltage 

      INFRARED RAY SENSOR - BODY GROUND AND BATTERY VOLTAGE

      Tester Connection Switch Condition Specified Condition
      X13-5(IG)-Body ground Engine switch on (IG) 11 to 14 V
      Engine switch off Below 1 V

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: REPLACE INFRARED RAY SENSOR (See  REMOVAL   )