Typical Enabling Conditions
All:
TYPICAL ENABLING CONDITIONS TABLE
| Output speed sensor circuit | Not circuit malfunction |
| Vehicle speed sensor circuit | Not circuit malfunction |
| Transfer neutral position switch | OFF |
ON malfunction (A)
TYPICAL ENABLING CONDITIONS TABLE
| Output speed (Transfer output speed) | 1,000 to 3,000 rpm |
ON malfunction (B)
TYPICAL ENABLING CONDITIONS TABLE
| Output speed (Transfer output speed) | 143 rpm or more |