Inspection Procedure
- CHECK DLC3 (TC TERMINAL VOLTAGE)
- Turn the ignition switch to ON.
- Measure the voltage of the DLC3.
Standard voltage: 10 to 14 V
OK: Go to step 3
NG: Go to next step
- CHECK HARNESS AND CONNECTOR (DLC3 - BODY GROUND)
- Check for open and short circuit in harness and connector between terminal CG of DLC3 and body ground (See ELECTRONIC CIRCUIT INSPECTION PROCEDURE ).
NG REPAIR OR REPLACE HARNESS OR CONNECTOR (DLC3 - BODY GROUND)
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (DLC3 - BODY GROUND)
- Check for open and short circuit in harness and connector between terminal TC of DLC3 and ECM (See
ELECTRONIC CIRCUIT INSPECTION PROCEDURE
).
NG REPAIR OR REPLACE HARNESS OR CONNECTOR OR EACH ECU
OK: Go to next step
CHECK AND REPLACE ECM
- Check for open and short circuit in harness and connector between terminal TC of DLC3 and ECM (See
ELECTRONIC CIRCUIT INSPECTION PROCEDURE
).