Ultrasonic Sensor: Inspection
- INSPECT NO. 1 ULTRASONIC SENSOR
- Measure the resistance of the sensor.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 (E) - 2 (S) Always 600 to 1,200 kΩ NOTE: Set the tester to the 100 kΩ range before performing the measurement.If the result is not as specified, replace the ultrasonic sensor.
- Measure the resistance of the sensor.
- INSPECT NO. 2 ULTRASONIC SENSOR
- Measure the resistance of the sensor.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 (E) - 2 (S) Always 600 to 1,200 kΩ NOTE: Set the tester to the 100 kΩ range before performing the measurement.If the result is not as specified, replace the ultrasonic sensor.
- Measure the resistance of the sensor.
- INSPECT NO. 3 ULTRASONIC SENSOR
- Measure the resistance of the sensor.
Standard resistance:
RESISTANCE SPECIFICATIONTester Connection [Tester (+) - Tester (-)] Condition Specified Condition 3 (S) - 2 (E) Always 30 to 50 kΩ 2 (E) - 3 (S) Always 30 to 50 kΩ 1 (T) - 2 (E)(1) Always 230 to 430 kΩ 2 (E) - 1 (T)(1) Always 1 MΩ or higher Set the tester to the 100 kΩ range before performing the measurement. NOTE:(1) Measurement values may vary depending on the tester used. If results seem inaccurate, reverse the polarity (+-) and measure again. If the result is not as specified, replace the ultrasonic sensor.
- Measure the resistance of the sensor.