Ambient Temperature Sensor: Inspection
- REMOVE AMBIENT TEMPERATURE SENSOR
- Disconnect the connector.
- Using a clip remover, pull out the sensor from bumper reinforcement.
- INSPECT AMBIENT TEMPERATURE SENSOR RESISTANCE
Measure resistance between terminals at each temperature as shown in the chart.
TEMPERATURE SPECIFIED CONDITIONTemperature Specified condition 25°C (77°F) 1.6-1.8 kΩ 50°C (122°F) 0.5-0.7 kΩ If resistance is not as specified, replace the sensor.
- INSTALL AMBIENT TEMPERATURE SENSOR
- Push the sensor in bumper reinforcement.
- Connect the connector.