Monitor Strategy
MONITOR STRATEGY
| Related DTCs | P0101 | Mass air flow meter rationality |
|---|---|---|
| Required sensors/components | Main sensors/components | Mass air flow meter |
| Related sensors/components | Engine speed sensor, Engine coolant temperature sensor, Throttle position sensor | |
| Frequency of operation | Continuous | |
| Duration | 10 sec. (High voltage) | |
| 6 sec. (Low voltage) | ||
| MIL operation | 2 driving cycles | |
| Sequence of operation | None | |