Inspection Procedure
- CHECK FUSE
- Check the PWR NO. 4 fuse.
- NG: REPLACE FUSE
- OK: Go to next step.
- CHECK POWER WINDOW REGULATOR SWITCH ASSY REAR (POWER SOURCE)
- Disconnect the R15 power window regulator switch assy rear (LH side) connector.
- Check the voltage between terminal BDR (R15-12) connector of regulator switch and the body ground.
Standard: 10-14 V
- NG: REPAIR OR REPLACE WIRE HARNESS AND CONNECTOR
- OK: Go to next step.
- CHECK POWER WINDOW REGULATOR SWITCH ASSY REAR (GROUND)
- Disconnect the R15 power window regulator switch assy rear (LH side) connector.
- Check the continuity between terminal GND (R15-7) connector of regulator switch and the body ground.
Standard: Continuity
- NG: REPAIR OR REPLACE WIRE HARNESS AND CONNECTOR
- OK: GO TO FLOWCHART (POWER WINDOW REGULATOR MOTOR CIRCUIT) (See POWER WINDOW REGULATOR MOTOR ASSY LH CIRCUIT (REAR LH DOOR) )