Sensor Resistance Test
- Unplug compressor lock sensor connector, located at compressor. Measure resistance between sensor terminals at specified temperatures. See COMPRESSOR LOCK SENSOR RESISTANCE SPECIFICATIONS table.
- If resistance is not as specified, replace sensor. If resistance is within specification, inspect wiring harness and connectors between sensor and A/C-heater control panel. Repair as necessary. If wiring harness and connectors are okay, temporarily substitute a known-good A/C-heater control panel, then retest system.
COMPRESSOR LOCK SENSOR RESISTANCE SPECIFICATIONS
| Sensor Temperature - °F (°C) | Ohms |
|---|---|
| 77 (25) | 170-220 |
| 212 (100) | 210-290 |