NIPPONDENSO 10-CYL.: Notes
After refrigerant recovery process is completed, the amount of refrigerant oil removed from the old compressor must be measured and same amount of oil added to the replacement compressor. When replacing components, add specified NEW refrigerant oil. Refer to the COMPONENT REFRIGERANT OIL CAPACITIES
table.
COMPONENT REFRIGERANT OIL CAPACITIES
| Component |
Ounces |
| Compressor |
| ES300, SC300 & SC400 |
4.1 |
| GS300 & GS400 |
|
| LS400 |
4.8 |
| LX470 |
|
| Condenser |
| ES300 |
1.4-1.7 |
| GS300, GS400 & LS400 |
1.4 |
| SC300 & SC400 |
1.4 |
| LX470 |
1.4-1.7 |
| Evaporator |
| ES300, GS300, GS400, LS400 & LX470 |
1.4 |
| SC300 & SC400 |
1.4 |
| Receiver-Drier |
| ES300 |
0.7 |
| LS400 |
0.3 |
| SC300 & SC400 |
0.3 |