Control Relay (Actuator Solenoid)
- Remove control relay from actuator. See SOLENOID & CONTROL RELAY . Connect a jumper wire between battery positive terminal and 6-pin relay connector terminal No. 1. See Figure-10. Connect a second jumper wire between ground and 4-pin relay connector terminal No. 3.
- Check for continuity between 6-pin relay connector terminals No. 2 and 5. Ensure continuity is not present between 6-pin relay connector terminals No. 5 and No. 6. If continuity is not as specified, replace relay. If continuity readings are as specified, relay is okay.